es-pump-revert-to-manual

If CGM fails or is removed, revert the insulin pump to manual mode provided basic criteria for pump use in hospital are still met. Trigger phrase: "CGM failed, should we switch pump to manual mode?

The English summary is being prepared. Showing the original description.

Run score Not tested

See how to install

Files included (1)

  • SKILL.md2.7 KB

SKILL.md (original)

Review the instructions the agent will receive before you install.

Revert insulin pump to manual mode if CGM fails or is removed

STEP 1 — Gather Information

  • Confirm CGM failure or removal (sensor error, dislodgement, patient report).
  • Assess patient ability to self-manage pump (alert, competent, no impaired consciousness).
  • Verify absence of contraindications to pump use: not in ICU, no DKA/HHS, no severe hypoglycemia unawareness.
  • Ensure pump supplies (infusion sets, reservoirs, insulin) are available for duration of hospitalization.
  • Check hospital policies and availability of expertise for pump management.

STEP 2 — Rule In / Rule Out

  • Is CGM failed or removed?
    • Yes → proceed to Step 3.
    • No → continue pump with CGM-guided automation and routine POC-BG confirmation.

STEP 3 — Classify or Stratify

  • Are basic criteria for pump use in hospital still met?
    • Yes → proceed to Step 4 (revert to manual mode).
    • No → transition to scheduled subcutaneous basal bolus insulin therapy (see Table 3 for conversion).

STEP 4 — Decide

  • If criteria met: switch pump to manual mode (disable automated features, use pre-set basal rates and manual bolus calculations).
  • Order frequent POC-BG monitoring (e.g., every 4–6 hours or per institutional protocol) to guide manual dosing.
  • Document mode change and notify nursing/pharmacy.

Clinical Guardrails / Mimics / Pitfalls

  • Do not revert to manual mode if patient cannot safely adjust pump settings (e.g., altered mental status, delirium).
  • Avoid manual mode in patients with active DKA, HHS, or requiring vasopressors; transition to IV insulin instead.
  • Ensure backup glucose monitoring is in place; reliance on CGM alone is unsafe after failure.
  • Do not assume pump function is intact; verify infusion set integrity and insulin potency.
  • Pitfall: continuing automated pump modes with erroneous CGM data can cause hypoglycemia or hyperglycemia.

Concrete Clinical Example

A 62-year-old woman with type 1 diabetes on hybrid closed-loop pump admitted for cholecystectomy. On postoperative day 1, her CGM displays persistent "sensor error" alerts. She is alert, able to troubleshoot pump, has spare supplies, and no ICU stay. The team confirms CGM failure, verifies she meets pump-use criteria, reverts the pump to manual mode, and orders POC-BG checks every 6 hours.

Source: Management of Hyperglycemia in Hospitalized Adult Patients in Non-Critical Care Settings: An Endocrine Society Clinical Practice Guideline, Endocrine Society, 2022, https://doi.org/10.1210/clinem/dgac278

Reviews

No reviews yet. Tell others what you thought.

Comments

No login needed. Share how it worked for you, ask a question, or note where it did not run.

No comments yet. Be the first to write one.

Comments are published right away. Do not include personal information such as email addresses or phone numbers. Up to 2 URLs.

0 / 1,000 characters

This form is protected by reCAPTCHA, and the Google Privacy Policy and Terms of Service apply.

More skills from this repository

Guide pump setting adjustments for the MiniMed 780G system based on CareLink data, using Medtronic's 3-step follow-up workflow. Use when a clinician has CareLink data for a 780G patient and wants to know what to change — which setting, by how much, and how to program it. Triggers include: "what do I adjust", "how to fix high TIR", "how to reduce hypos", "adjust ICR/ISF/basal", "SmartGuard settings", "780G pump settings review", or any question about optimising 780G therapy after reviewing a download.

The English summary is being prepared. Showing the original description.

dromlakhani/MD2SKILL14Updated Oct 20, 2026

Performs corticotropin stimulation test to diagnose adrenal insufficiency when morning cortisol is indeterminate (3-15 µg/dL). Triggers include morning cortisol 3-15 µg/dL requiring further AI testing.

The English summary is being prepared. Showing the original description.

dromlakhani/MD2SKILL14Updated Oct 20, 2026

Administers immediate parenteral injection of 50–100 mg hydrocortisone for suspected adrenal crisis secondary to adrenal insufficiency. Triggers include hypotension, hypoglycemia, or acute illness in a patient with known adrenal insufficiency.

The English summary is being prepared. Showing the original description.

dromlakhani/MD2SKILL14Updated Oct 20, 2026

Clinicians educate adrenal insufficiency patients taking nondexamethasone glucocorticoids who initiate enzyme-inducing antiepileptic drugs about early signs of adrenal insufficiency. Trigger when an AI patient on nondexamethasone GC starts an enzyme-inducing AED such as phenytoin, carbamazepine, or oxcarbazepine.

The English summary is being prepared. Showing the original description.

dromlakhani/MD2SKILL14Updated Oct 20, 2026

In central hypothyroidism patients receiving levothyroxine who initiate enzyme‑inducing antiepileptic drugs, the guideline recommends checking free T4 at least 6 weeks after AED start and increasing the levothyroxine dose if free T4 falls below the target range. Triggers include: central hypothyroidism patient on levothyroxine starting antiepileptic drug such as phenytoin, carbamazepine, or oxcarbazepine.

The English summary is being prepared. Showing the original description.

dromlakhani/MD2SKILL14Updated Oct 20, 2026

Applies serum cortisol cutoffs (<3 μg/dL indicates central adrenal insufficiency; >15 μg/dL likely excludes it) when evaluating morning cortisol for suspected adrenal insufficiency. Triggers include morning cortisol measurement in suspected AI and use when interpreting morning cortisol levels for adrenal insufficiency workup.

The English summary is being prepared. Showing the original description.

dromlakhani/MD2SKILL14Updated Oct 20, 2026

See all skills by dromlakhani

Report a problem with this skill