Skip to content
cccskills
FreePublished on GitHub

nmrglue

Process calibrated one-dimensional NMR signals into spectra, candidate peaks, and signed integration results. Supports manual phase adjustment, baseline correction, and recorded processing settings so results can be reviewed and reproduced.

OriginalShow the original description

Processes calibrated one-dimensional complex NMR free-induction decays with nmrglue into phased spectra, peak candidates, and signed integration regions. Use for raw 1D NMR processing, ppm-axis verification, apodization, Fourier transformation, manual phasing, baseline correction, or reproducible spectral integration.

Run score Not tested

See how to install

Good for

  • Convert raw one-dimensional NMR signals into spectra
  • Check peak positions against reference signals
  • Review phase and baseline corrections
  • Integrate specified spectral regions reproducibly

Files included (4)

  • SKILL.md8.3 KB
  • assets/processing.json364 B
  • references/acquisition-and-validation.md6.0 KB
  • scripts/process_1d.py10.5 KB

SKILL.md (original)

Review the instructions the agent will receive before you install.

nmrglue: calibrated 1D FID processing

When to use

Use for a uniformly sampled complex 1D FID whose acquisition parameters and complex frequency convention are available. The helper produces a descending ppm spectrum, positive peak candidates, signed region integrals, and a reproducible processing report. It does not identify compounds or assign resonances.

The executable accepts a NumPy .npz containing exactly one complex fid array or a canonical 1D complex time-domain NMRPipe file. NMRPipe reading is tested with a synthetic write/read round trip, known-spectrum recovery, and a small upstream NMRPipe-generated binary fixture. Experimental Bruker, Varian, and JEOL imports are not verified by this suite. For those formats, first inspect the relevant nmrglue reader and acquisition metadata. Opening a converted file does not validate the original acquisition decoding. Read references/acquisition-and-validation.md for conversion boundaries, axis calibration, and quantitative limits.

Workflow

  1. Preserve the raw FID. Establish spectral width in Hz, positive observation frequency in MHz, carrier in ppm, observed nucleus, and the sign convention from the acquisition or a known reference. Determine whether digital-filter/group-delay removal has already occurred. Do not infer these from array length or typical instrument defaults.
  2. Copy assets/processing.json and replace its synthetic example values with the measured parameters and explicit processing choices. Its sign -i means a resonance at offset f = (ppm - carrier_ppm) * observation_mhz has time dependence exp(-2*pi*i*f*t). Select +i only for the opposite convention; the helper conjugates it before processing. Validate with a known reference peak.
  3. Choose nonnegative exponential line broadening (Hz), an even zero-filled size at least as large as the acquired FID, first-point scaling, and phase angles. Zero filling improves interpolation, not acquired spectral resolution. First-point scaling 0.5 is suitable for the supplied causal synthetic example; acquisition and prior preprocessing may require another value.
  4. Run the helper, inspect the real and imaginary spectra, and revise manual phase if needed. phase0_deg + phase1_deg * index / zero_fill_points is applied after FT; index zero is the high-ppm edge. There is no implicit pivot or automatic phase estimate.
  5. Only fit a linear baseline when explicitly supplied ppm regions are signal-free. Set baseline to linear and add baseline_regions_ppm containing at least two regions. Inspect residuals and broad peaks; fitting through signals biases integrals.
  6. Compare peak positions with references, inspect peak candidates for artifacts, and integrate specified regions. Report overlapped peaks as overlapped. Preserve negative areas as diagnostic evidence of phase/baseline problems instead of taking absolute values.

Execute

Tested with Python 3.12, nmrglue 0.12, NumPy 2.5.3, and SciPy 1.18.1:

uv run --no-project --python 3.12 --with nmrglue==0.12 --with numpy==2.5.3 --with scipy==1.18.1 \
  python skills/nmrglue/scripts/process_1d.py fid.npz processing.json nmr-result

Paths assume the collection root. Adjust them when installed elsewhere. The output directory must be new, so repeated processing keeps previous results reviewable.

For an existing 1D NMRPipe FID, add --input-format nmrpipe and supply its path in place of fid.npz. The helper requires the canonical FDF2 direct dimension, complex quadrature, a time-domain flag, and agreement between header and JSON spectral width, observation frequency, and carrier. JSON settings remain explicit; a mismatch fails instead of silently recalibrating. FDF2TDSIZE must equal the stored complex-point count, and FDF2CENTER / FDF2ORIG must describe a canonical centered axis. Previously zero-filled, truncated, or recentered files need a separate acquisition-aware workflow. The nucleus/complex sign and previous digital-filter corrections still need acquisition evidence. A time-domain flag alone does not establish an unprocessed FID.

This executable synthetic example matches the supplied settings, generates resonances at 3 and 7 ppm in a 1:2 amplitude ratio, and does not represent an experimental sample:

import numpy as np

t = np.arange(8192) / 4000.0
fid = sum(a * np.exp(-np.pi * 2.0 * t)
          * np.exp(-2j * np.pi * (ppm - 5.0) * 400.0 * t)
          for ppm, a in [(3.0, 1.0), (7.0, 2.0)])
np.savez("fid.npz", fid=fid)

Run it with assets/processing.json as the settings argument. The repository suite executes this signal and the CLI, checks both peak locations within 0.001 ppm, checks integral ratio and analytic area, and checks phase and baseline recovery. The NMRPipe round-trip test writes this FID using ng.pipe.create_dic/ng.pipe.write, reads it through the CLI, and verifies the recovered peaks and integral ratio. Processed frequency-domain files and conflicting calibration metadata are rejected.

The 2,176-byte upstream fixture checks complex sample order and header calibration using a file generated by NMRPipe's simTimeND / SET tools. Those native tools were not run in this review; this is fixture compatibility, not a live NMRPipe processing comparison.

Deliverables and interpretation

  • spectrum.csv: descending ppm, real signal after baseline correction, phased imaginary signal, and the fitted real baseline. Plot NMR with the high-ppm end on the left.
  • report.json: input/settings SHA-256, package versions, all settings, acquired duration, zero-filled digital spacing, positive peak candidates, and signed region areas.

Integrals use endpoint interpolation and trapezoidal integration along increasing ppm; area units are arbitrary signal times ppm, independent of display direction. Regions outside the sampled ppm axis fail rather than being silently clipped. Peak prominence is a fraction of the largest positive real intensity; it is not a noise-derived detection limit. Strong solvent signals can obscure weak candidates at the default threshold.

For quantitative NMR, additionally establish relaxation delay, pulse angle, saturation, receiver behavior, internal/external reference amount, and integration uncertainty. The helper does not calculate concentrations or correct unequal relaxation. Preserve these limits with the result rather than converting arbitrary areas to molecule counts.

Upstream contracts

The hosted latest documentation identified itself as 0.9-dev when checked; the actual 0.12 package APIs and numerical behavior were tested. Its proc_base.fft uses the negative-exponent NumPy FFT followed by fftshift; NMRPipe's FT convention corresponds to fft_positive, so do not substitute it without revisiting the FID sign and phase. See the v0.12 processing source. Multidimensional processing, nonuniform sampling, automated assignment, and experimental vendor imports remain outside this helper's validated scope.

Reviews

No reviews yet. Tell others what you thought.

Comments

No login needed. Share how it worked for you, ask a question, or note where it did not run.

No comments yet. Be the first to write one.

Comments are published right away. Do not include personal information such as email addresses or phone numbers. Up to 2 URLs.

0 / 1,000 characters

This form is protected by reCAPTCHA, and the Google Privacy Policy and Terms of Service apply.

More skills from this repository

Estimate intracellular reaction rates from steady-state carbon-13 tracing measurements. Validate carbon atom mappings and measurement inputs, simulate labeling, fit constrained fluxes, and diagnose which pathway rates the data can meaningfully constrain.

  • Estimate metabolic fluxes from carbon-13 labeling
  • Validate atom mappings and measurement inputs
  • Simulate labeling for proposed reaction rates
K-Dense-AI/scientific-agent-skills54.2KUpdated Oct 19, 2026

adaptyv

FreeSummary

Plan protein characterization experiments with Adaptyv's cloud laboratory, estimate costs, submit sequences, track progress, and retrieve measured results. Supports binding, thermal stability, expression, fluorescence, and enzyme activity workflows through the API and Python SDK.

  • Plan binding screens for candidate protein sequences
  • Estimate experiment costs before submission
  • Track laboratory progress and retrieve results
K-Dense-AI/scientific-agent-skills54.2KUpdated Oct 19, 2026

aeon

FreeSummary

Analyze time series with aeon, a Python toolkit for data that changes over time. Supports classification, regression, clustering, forecasting, anomaly detection, and pattern search, with guidance on preprocessing, algorithm selection, and evaluation.

  • Classify time series and predict continuous outcomes
  • Group time series with similar patterns
  • Forecast future values
K-Dense-AI/scientific-agent-skills54.2KUpdated Oct 19, 2026

alphagenome

FreeSummary

Investigate how DNA variants may affect gene activity using precomputed AlphaGenome Atlas results and model predictions. Rank candidate variants, examine tissue-specific effects, and inspect the features behind scores to develop research hypotheses about biological mechanisms.

  • Ranking candidate variants from a VCF
  • Examining tissue-specific effects on gene activity
  • Comparing reference and altered DNA predictions
K-Dense-AI/scientific-agent-skills54.2KUpdated Oct 19, 2026

Plan and document studies that assess whether an analytical procedure suits its intended use. Select the governing framework, evaluate calibration, accuracy, precision, and detection limits, and compare methods using acceptance criteria defined before data collection.

  • Planning analytical validation studies and acceptance criteria
  • Evaluating calibration, accuracy, and precision
  • Estimating and confirming detection and quantitation limits
K-Dense-AI/scientific-agent-skills54.2KUpdated Oct 19, 2026

anndata

FreeSummary

Organize single-cell measurements with cell and gene metadata, read and write h5ad or Zarr files, and prepare subsets or combined datasets. Includes guidance on handling large annotated matrices without loading all measurement values into memory.

  • Read and write h5ad or Zarr datasets
  • Combine experimental batches with source labels
  • Select cells or genes using metadata
K-Dense-AI/scientific-agent-skills54.2KUpdated Oct 19, 2026

See all skills by K-Dense-AI

Report a problem with this skill