본문으로 건너뛰기
cccskills
무료GitHub에 공개

serial-debug

CLI-first serial port debugging and macro automation with serial-mcp-server for Codex and Claude Code. Use when working with UART or USB-serial devices, listing serial ports, probing STM32/Arduino/ESP32 boards, writing or reading serial data, running JSON serial macros, controlling RTS/DTR, or using serial-mcp-server through MCP tools.

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

설치 방법 보기

포함된 파일(6)

  • SKILL.md2.6 KB
  • agents/openai.yaml192 B
  • references/cli.md3.2 KB
  • references/hardware-safety.md1.1 KB
  • references/mcp.md2.2 KB
  • references/troubleshooting.md1.1 KB

SKILL.md(원문)

설치하기 전에 에이전트에게 전달되는 지시 내용을 확인할 수 있습니다.

Serial Debug

Operating Rule

Use the serial-mcp-server CLI first unless the user explicitly asks for MCP or an MCP client is already configured. Keep stdout data separate from diagnostics, cite exact commands, and base hardware success on real command evidence from the device.

Workflow

  1. Confirm the binary is available:
serial-mcp-server --help
  1. List available ports before choosing a device:
serial-mcp-server list-ports --json
  1. For a device smoke test, probe the port first, then write/read only when the probe succeeds:
serial-mcp-server probe --port <port> --baud 115200 --json
serial-mcp-server write --port <port> --baud 115200 --data H --read --timeout-ms 1000 --json
  1. If RTS or DTR is involved, state the requested line levels and use the control-line command:
serial-mcp-server set-control-lines --port <port> --rts high --dtr low --json
  1. For repeatable serial procedures, prefer JSON macro packs and validate or plan them before real hardware execution:
serial-mcp-server macro validate --file <pack.json> --json
serial-mcp-server macro plan --file <pack.json> --macro <name> --json
serial-mcp-server macro run --file <pack.json> --macro <name> --simulate-read <response> --json
serial-mcp-server macro run --file <pack.json> --macro <name> --port <port> --baud 115200 --json

Macro packs are restricted JSON DSL files. v0.3 supports send, delay, expect contains, expect equals, and assemblies that call macros. It does not support shell commands, language execution, loops, variables, Quick commands, or RTS/DTR macro steps.

References

  • Read references/cli.md for exact command behavior, output expectations, and automation rules.
  • Read references/mcp.md when the user asks for MCP setup or MCP tool usage.
  • Read references/hardware-safety.md before changing baud, wiring, voltage levels, RTS, DTR, or reset/boot lines.
  • Read references/troubleshooting.md when a command fails, times out, returns no ports, or cannot open the device.

Reporting

Report the command, exit status, and the relevant JSON or error excerpt. If no hardware is connected, limit the validation summary to discovery and help paths.

리뷰

아직 리뷰가 없습니다. 사용해 본 소감을 남겨 주세요.

댓글

로그인 없이 쓸 수 있습니다. 사용 후기, 질문, 작동하지 않은 환경 등을 편하게 남겨 주세요.

아직 댓글이 없습니다. 첫 댓글을 남겨 보세요.

보내면 바로 공개됩니다. 이메일 주소나 전화번호 같은 개인 정보는 쓰지 마세요. URL은 2개까지입니다.

0 / 1,000자

이 양식은 reCAPTCHA로 보호되며 Google 개인정보처리방침 및 서비스 약관이 적용됩니다.

이 스킬의 문제 신고