본문으로 건너뛰기
cccskills
무료GitHub에 공개

bio-flow-cytometry-doublet-detection

Detect and remove doublets from flow and mass cytometry data. Covers FSC/SSC gating and computational doublet detection methods. Use when filtering out cell aggregates before clustering or quantitative analysis.

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

설치 방법 보기

포함된 파일(3)

  • SKILL.md7.7 KB
  • examples/detect_doublets.R4.1 KB
  • usage-guide.md2.3 KB

SKILL.md(원문)

설치하기 전에 에이전트에게 전달되는 지시 내용을 확인할 수 있습니다.

Version Compatibility

Reference examples tested with: flowCore 2.14+, ggplot2 3.5+

Before using code patterns, verify installed versions match. If versions differ:

  • R: packageVersion('<pkg>') then ?function_name to verify parameters

If code throws ImportError, AttributeError, or TypeError, introspect the installed package and adapt the example to match the actual API rather than retrying.

Doublet Detection

"Remove doublets from my flow cytometry data" → Detect and filter out cell aggregates using FSC-A/FSC-H gating or computational methods before clustering or quantitative analysis.

  • R: flowCore rectangular gates on FSC-A vs FSC-H

FSC-A vs FSC-H Gating (Standard Method)

library(flowCore)
library(ggcyto)

# Load data
fs <- read.flowSet(list.files('data/', pattern = '\\.fcs$', full.names = TRUE))

# FSC-A vs FSC-H for doublet discrimination
# Singlets fall on diagonal, doublets have higher FSC-A for given FSC-H

# Manual rectangular gate
singlet_gate <- rectangleGate(
    filterId = 'singlets',
    'FSC-A' = c(50000, 250000),
    'FSC-H' = c(50000, 250000)
)

# Or use polygon gate for diagonal
singlet_polygon <- polygonGate(
    filterId = 'singlets',
    .gate = data.frame(
        'FSC-A' = c(50000, 250000, 250000, 50000),
        'FSC-H' = c(40000, 200000, 260000, 60000)
    )
)

# Apply gate
singlets <- Subset(fs, singlet_gate)

# Visualize
autoplot(fs[[1]], 'FSC-A', 'FSC-H') + geom_gate(singlet_gate)

Automated Singlet Gating with flowDensity

library(flowDensity)

# Automatic singlet gate
singlet_result <- flowDensity(
    fs[[1]],
    channels = c('FSC-A', 'FSC-H'),
    position = c(TRUE, TRUE),
    gates = c(NA, NA)
)

# Get gated population
singlets <- getflowFrame(singlet_result)

# Percentage singlets
pct_singlets <- nrow(singlets) / nrow(fs[[1]]) * 100
cat('Singlets:', round(pct_singlets, 1), '%\n')

flowAI Quality Control

library(flowAI)

# flowAI performs comprehensive QC including:
# - Flow rate anomaly detection
# - Signal acquisition anomaly detection
# - Dynamic range anomaly detection

# Run flowAI
fs_qc <- flow_auto_qc(
    fs,
    folder_results = 'flowAI_results',
    fcs_QC = TRUE,
    fcs_highQ = TRUE
)

# Results include singlet detection based on flow rate stability

FSC-A/FSC-W Method (Width Parameter)

# Some instruments provide FSC-W (width) instead of FSC-H
# FSC-A = FSC-H × FSC-W
# Doublets have higher width

if ('FSC-W' %in% colnames(fs[[1]])) {
    singlet_gate_w <- rectangleGate(
        filterId = 'singlets',
        'FSC-A' = c(50000, 250000),
        'FSC-W' = c(50000, 100000)  # Lower width = singlets
    )

    singlets <- Subset(fs, singlet_gate_w)
}

Ratio-Based Doublet Detection

# Calculate FSC-A/FSC-H ratio
# Singlets have ratio close to constant (based on pulse geometry)
# Doublets have elevated ratio

calculate_fsc_ratio <- function(ff) {
    fsc_a <- exprs(ff)[, 'FSC-A']
    fsc_h <- exprs(ff)[, 'FSC-H']

    ratio <- fsc_a / (fsc_h + 1)  # Add small value to avoid division by zero
    return(ratio)
}

# Add ratio as derived parameter
for (i in 1:length(fs)) {
    ratio <- calculate_fsc_ratio(fs[[i]])
    fs[[i]] <- cbind2(fs[[i]], ratio)
    colnames(fs[[i]])[ncol(fs[[i]])] <- 'FSC_ratio'
}

# Gate on ratio
ratio_cutoff <- quantile(exprs(fs[[1]])[, 'FSC_ratio'], 0.95)
singlet_gate_ratio <- rectangleGate(filterId = 'singlets', 'FSC_ratio' = c(0, ratio_cutoff))

SSC-Based Doublet Detection

# For cell types where FSC doesn't discriminate well,
# use SSC-A vs SSC-H additionally

ssc_singlet_gate <- rectangleGate(
    filterId = 'ssc_singlets',
    'SSC-A' = c(10000, 200000),
    'SSC-H' = c(10000, 200000)
)

# Combine FSC and SSC gates
combined_gate <- singlet_gate & ssc_singlet_gate
singlets <- Subset(fs, combined_gate)

CyTOF Doublet Detection

library(CATALYST)

# For CyTOF data, use DNA channels or event length

# DNA-based doublet detection (if DNA channels present)
# Doublets have ~2x DNA content
sce <- prepData(fs, panel, md)

# If Event_length channel exists
if ('Event_length' %in% rownames(sce)) {
    event_length <- assay(sce)['Event_length', ]
    singlet_idx <- event_length < quantile(event_length, 0.95)

    sce_singlets <- sce[, singlet_idx]
    cat('Removed', sum(!singlet_idx), 'doublets based on event length\n')
}

# DNA intercalator method
if (all(c('DNA1', 'DNA2') %in% rownames(sce))) {
    dna_total <- assay(sce)['DNA1', ] + assay(sce)['DNA2', ]
    dna_cutoff <- quantile(dna_total, 0.95)

    singlet_idx <- dna_total < dna_cutoff
    sce_singlets <- sce[, singlet_idx]
}

CATALYST Workflow with Doublet Removal

Goal: Detect and remove cell doublets from a CyTOF/flow dataset using a regression-based approach on scatter parameters.

Approach: Model the expected FSC-A vs FSC-H relationship for singlets with linear regression, classify events with large residuals (above the 95th percentile) as doublets, and filter them out.

library(CATALYST)

# Load and prepare data
sce <- prepData(fs, panel, md, transform = TRUE, cofactor = 5)

# Remove doublets using marker-based method
sce <- filterSCE(sce, !is_doublet(sce))

# Custom doublet detection based on FSC
fsc_a <- colData(sce)$FSC_A
fsc_h <- colData(sce)$FSC_H

# Model expected singlet relationship
fit <- lm(fsc_a ~ fsc_h)
residuals <- abs(fsc_a - predict(fit))
threshold <- quantile(residuals, 0.95)

# Mark doublets
colData(sce)$doublet <- residuals > threshold
sce_singlets <- sce[, !colData(sce)$doublet]

cat('Doublet rate:', round(mean(colData(sce)$doublet) * 100, 1), '%\n')

Batch Processing

# Process all samples
detect_doublets <- function(ff, method = 'fsc') {
    if (method == 'fsc') {
        fsc_a <- exprs(ff)[, 'FSC-A']
        fsc_h <- exprs(ff)[, 'FSC-H']

        fit <- lm(fsc_a ~ fsc_h)
        residuals <- abs(fsc_a - predict(fit))
        threshold <- quantile(residuals, 0.95)

        singlet_idx <- residuals <= threshold
    } else if (method == 'ratio') {
        ratio <- exprs(ff)[, 'FSC-A'] / (exprs(ff)[, 'FSC-H'] + 1)
        singlet_idx <- ratio < quantile(ratio, 0.95)
    }

    return(ff[singlet_idx, ])
}

# Apply to all samples
fs_singlets <- fsApply(fs, detect_doublets, method = 'fsc')

# Report
doublet_rates <- sapply(1:length(fs), function(i) {
    1 - nrow(fs_singlets[[i]]) / nrow(fs[[i]])
})
cat('Mean doublet rate:', round(mean(doublet_rates) * 100, 1), '%\n')

Visualization

library(ggplot2)

# Extract data for plotting
plot_data <- data.frame(
    FSC_A = exprs(fs[[1]])[, 'FSC-A'],
    FSC_H = exprs(fs[[1]])[, 'FSC-H']
)

# Calculate doublet status
fit <- lm(FSC_A ~ FSC_H, data = plot_data)
plot_data$residual <- abs(plot_data$FSC_A - predict(fit))
plot_data$doublet <- plot_data$residual > quantile(plot_data$residual, 0.95)

# Plot
ggplot(plot_data, aes(x = FSC_H, y = FSC_A, color = doublet)) +
    geom_point(alpha = 0.3, size = 0.5) +
    scale_color_manual(values = c('gray', 'red')) +
    theme_bw() +
    labs(title = 'Doublet Detection', x = 'FSC-H', y = 'FSC-A')
ggsave('doublet_detection.png', width = 8, height = 6)

Related Skills

Workflow order: cytometry-qc → doublet-detection → bead-normalization → clustering

  • cytometry-qc - Run first: identify flow rate and signal issues
  • bead-normalization - Run after: correct remaining instrument drift
  • fcs-handling - Load FCS files
  • gating-analysis - Manual gating workflows
  • clustering-phenotyping - Downstream analysis after doublet removal

리뷰

아직 리뷰가 없습니다. 사용해 본 소감을 남겨 주세요.

댓글

로그인 없이 쓸 수 있습니다. 사용 후기, 질문, 작동하지 않은 환경 등을 편하게 남겨 주세요.

아직 댓글이 없습니다. 첫 댓글을 남겨 보세요.

보내면 바로 공개됩니다. 이메일 주소나 전화번호 같은 개인 정보는 쓰지 마세요. URL은 2개까지입니다.

0 / 1,000자

이 양식은 reCAPTCHA로 보호되며 Google 개인정보처리방침 및 서비스 약관이 적용됩니다.

같은 저장소의 스킬

Workflow for read alignment, sorting, indexing, mapping statistics, and downstream-ready alignment artifacts.

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

BioTender-max/awesome-bio-agent-skills2042026년 7월 2일 업데이트

alphafold

무료

Validate protein designs using AlphaFold2 structure prediction. Use this skill when: (1) Validating designed sequences fold correctly, (2) Predicting binder-target complex structures, (3) Calculating confidence metrics (pLDDT, pTM, ipTM), (4) Self-consistency validation of designs, (5) Multi-chain complex prediction with AlphaFold-Multimer. For faster single-chain prediction, use esm. For QC thresholds, use protein-qc.

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

BioTender-max/awesome-bio-agent-skills2042026년 7월 2일 업데이트

AlphaFold2 / AlphaFold-Multimer structure prediction for validation and confidence scoring. Use this skill when: (1) Validating designed sequences fold correctly, (2) Predicting binder-target complex structures, (3) Calculating confidence metrics (pLDDT, pTM, ipTM), (4) Self-consistency validation of designs, (5) Multi-chain complex prediction with AlphaFold-Multimer. For faster single-chain prediction, use esm2-sequence-scoring. For QC thresholds, use protein-design-qc.

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

BioTender-max/awesome-bio-agent-skills2042026년 7월 2일 업데이트

Workflow for event-level and isoform-level splicing analysis with sashimi-ready outputs and splice QC.

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

BioTender-max/awesome-bio-agent-skills2042026년 7월 2일 업데이트

atac-seq

무료

ATAC-seq processing with assay QC, MACS3 peak calling, consensus peak matrices, differential accessibility, and motif or footprint follow-up.

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

BioTender-max/awesome-bio-agent-skills2042026년 7월 2일 업데이트

bindcraft

무료

End-to-end binder design using BindCraft hallucination. Use this skill when: (1) Designing protein binders with built-in AF2 validation, (2) Running production-quality binder campaigns, (3) Using different design protocols (fast, default, slow), (4) Need joint backbone and sequence optimization, (5) Want high experimental success rate. For backbone-only generation, use rfdiffusion. For QC thresholds, use protein-qc. For tool selection guidance, use binder-design.

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

BioTender-max/awesome-bio-agent-skills2042026년 7월 2일 업데이트

BioTender-max의 스킬 모두 보기

이 스킬의 문제 신고