본문으로 건너뛰기
cccskills
무료GitHub에 공개

advmat-methods

Use when deciding what characterization and experimental detail an Advanced Materials manuscript must show to prove its structure–property claim, and what belongs in the Experimental Section and Supporting Information. Partitions and stress-tests methods; does not design figures or run analysis.

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

설치 방법 보기

포함된 파일(1)

  • SKILL.md5.9 KB

SKILL.md(원문)

설치하기 전에 에이전트에게 전달되는 지시 내용을 확인할 수 있습니다.

Advanced Materials Methods & Characterization (advmat-methods)

When to trigger

  • Your structure or phase assignment rests on a single technique
  • A reviewer of a prior draft asked "how do you know it is this phase / this mechanism?"
  • The device metric has no benchmarking against comparable state-of-the-art systems
  • The Experimental Section sprawls, or you cannot tell what belongs in the body vs. the SI
  • Reproducibility is thin: batch-to-batch spread, synthesis provenance, or statistics are missing

The multi-technique principle

An Adv. Mater. claim about a material must be triangulated by complementary techniques, not asserted from one. A single XRD pattern or one TEM image is rarely enough; referees expect the structure–composition–property picture to close from several independent angles.

A practical characterization matrix (adapt to your material class):

Claim you are makingDo not rely on one technique — triangulate with
Crystal structure / phaseXRD (+ Rietveld) and electron diffraction (SAED) / HRTEM lattice
Morphology / size / architectureSEM and TEM (+ statistics over many particles, not one hero image)
Composition / oxidation stateXPS and EDS/EELS mapping and ICP-MS/AES for bulk stoichiometry
Local bonding / defectsRaman / FTIR / XAS (XANES/EXAFS), NMR where applicable
Optoelectronic propertyUV-vis / PL / TAS + the transport or device measurement it predicts
Electrochemical performanceCV + galvanostatic cycling + rate/stability data + post-mortem analysis

State uncertainties and sample counts. "n = 3 devices, mean ± s.d." beats a single best cell.

Benchmarking is not optional

Adv. Mater. device claims live or die on fair comparison to the state of the art. Put the comparison in the paper, on equal footing:

  • Compare against the best reported systems for the same function, under comparable conditions — cite them.
  • Report the metric with its measurement protocol (scan rate, illumination, active area, humidity) so it is comparable.
  • If you claim a record, show a benchmark table or plot (e.g. an efficiency-vs-stability or Ragone-style comparison) rather than a bare number.

Body vs. Experimental Section vs. Supporting Information

Detail typeMain text / Experimental SectionSupporting Information
Core synthesis route + key parametersExperimental Section (reproducible)full optimization sweeps
The decisive characterization proving the claimmain-text figureextended datasets, more samples
Device fabrication + measurement protocolExperimental Sectionfull protocols, control devices
Benchmarking vs. state of the artmain textfull comparison table + refs
Statistics on the headline metricmain text (n, mean ± s.d.)per-sample data, histograms
Instrument models / settingsExperimental Section (concise)exhaustive parameters

The Experimental Section must let a competent group reproduce the material. Detail that is essential-but-bulky (full recipes, calibration, secondary controls) goes to the SI and is cited inline.

Rigor without bulk

  • Pre-empt the leading alternative explanation for your structure/property claim in the body, briefly, and point to the SI for the exhaustive checks.
  • Report purity/phase fraction, not just "phase-pure" as an adjective.
  • Give data-availability and, where relevant, computational details (see resources/external_tools.md for the DFT/simulation stack).

Checklist

  • Every structural/compositional claim is supported by ≥2 complementary techniques
  • Morphology/size claims carry statistics, not a single hero image
  • The headline metric is benchmarked against cited state-of-the-art systems, fairly
  • Device metrics report the full measurement protocol (area, conditions, scan rate)
  • The headline number carries a sample count and spread (n, mean ± s.d.)
  • The Experimental Section is reproducible; bulky detail is in the SI and cited
  • The leading alternative explanation is named and addressed

Anti-patterns

  • A single-technique structure claim ("XRD confirms the phase") with no corroboration
  • One flattering TEM/SEM image standing in for a distribution
  • A record metric with no benchmarking and no measurement conditions
  • Reporting one best device and hiding batch-to-batch variability
  • An Experimental Section too vague to reproduce, or so long it belongs in the SI
  • "Data available on request" instead of a concrete availability statement

Output format

【Central material claim】...
【Triangulation】technique 1 / technique 2 / technique 3 — sufficient?  yes / add: ...
【Morphology statistics】present?  yes / fix
【Benchmarking vs. SOTA】in main text, fair, cited?  yes / fix
【Metric statistics】n + spread stated?  yes / fix
【Reproducibility】Experimental Section reproducible?  yes / fix
【Next】advmat-figures (characterization figure) or advmat-supplementary (SI partition)

Data-availability, reproducibility, and characterization-reporting expectations evolve — verify current Wiley Advanced Materials policy on the official author page.

리뷰

아직 리뷰가 없습니다. 사용해 본 소감을 남겨 주세요.

댓글

로그인 없이 쓸 수 있습니다. 사용 후기, 질문, 작동하지 않은 환경 등을 편하게 남겨 주세요.

아직 댓글이 없습니다. 첫 댓글을 남겨 보세요.

보내면 바로 공개됩니다. 이메일 주소나 전화번호 같은 개인 정보는 쓰지 마세요. URL은 2개까지입니다.

0 / 1,000자

이 양식은 reCAPTCHA로 보호되며 Google 개인정보처리방침 및 서비스 약관이 적용됩니다.

같은 저장소의 스킬

Use when packaging AAAI code, data, multimedia appendices, technical appendices, reproducibility evidence, and post-acceptance artifact releases without violating double-blind or immutable-supplement rules.

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

brycewang-stanford/Awesome-Journal-Skills1.3천2026년 9월 27일 업데이트

Use when drafting an AAAI author response (rebuttal) under the single short character-limited author-feedback window, the no-URL rule, no-new-results guidance, AI-generated-review handling, and the AAAI two-phase review process where Phase-2 papers receive one feedback round before SPC/AC discussion.

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

brycewang-stanford/Awesome-Journal-Skills1.3천2026년 9월 27일 업데이트

Use when preparing an accepted AAAI paper for camera-ready source submission to AAAI Press, including proceedings page limits, two-column template compliance, copyright transfer, purchased extra technical pages, deanonymization, registration, oral or poster presentation, and final public artifact release.

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

brycewang-stanford/Awesome-Journal-Skills1.3천2026년 9월 27일 업데이트

Use when designing or auditing AAAI experiments for the broad-AI program committee, including baselines, ablations, statistical significance, robustness, human evaluation, AI-for-Social-Impact and alignment/safety evidence, compute and cost reporting, and reproducibility-checklist alignment for Phase-1 survival.

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

brycewang-stanford/Awesome-Journal-Skills1.3천2026년 9월 27일 업데이트

Use when positioning an AAAI paper's novelty against archival work, contemporaneous arXiv or workshop papers, and AAAI/IJCAI/NeurIPS/ICML/ICLR neighbors across the broad AI scope, while staying inside AAAI's dual-submission and AI-as-source policy constraints and writing a related-work section legible to non-specialist reviewers.

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

brycewang-stanford/Awesome-Journal-Skills1.3천2026년 9월 27일 업데이트

Use when strengthening an AAAI paper's reproducibility checklist (placed after references), experimental traceability, seed and hyperparameter reporting, compute and cost disclosure, dataset access and licensing, code/data ZIP readiness, and the claim-to-evidence map that Phase-1 reviewers use to judge rigor across AAAI's broad AI scope.

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

brycewang-stanford/Awesome-Journal-Skills1.3천2026년 9월 27일 업데이트

brycewang-stanford의 스킬 모두 보기

이 스킬의 문제 신고