본문으로 건너뛰기
cccskills
무료GitHub에 공개

building-simulink-models

Builds and edits Simulink, System Composer, Stateflow, and Simscape models. Use when modifying model structure, parameters, ports, connections, or Stateflow chart internals.

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

설치 방법 보기

포함된 파일(5)

  • SKILL.md9.2 KB
  • manifest.yaml845 B
  • references/simscape.md2.9 KB
  • references/stateflow.md9.4 KB
  • references/system-composer.md3.7 KB

SKILL.md(원문)

설치하기 전에 에이전트에게 전달되는 지시 내용을 확인할 수 있습니다.

Building Models

Use model_edit for all structural changes — Simulink, System Composer, Simscape, and Stateflow chart internals

When to Use

  • Adding, connecting, deleting, or replacing blocks in a model
  • Configuring block parameters, signal properties, or model settings
  • Creating or editing Stateflow chart internals (states, transitions, junctions, data, events, messages, functions)
  • Building System Composer architecture models
  • Wiring Simscape physical connections

When NOT to Use

  • Querying parameter values → use model_query_params
  • Resolving variable references to numeric values → use model_resolve_params

Library & Policy Prerequisites — BLOCKING GATE

Do this FIRST — evaluate the result before any other tool call. Do not narrate the gate check to the user; proceed silently based on the result.

Call library.settingsLookup() to check for custom library configuration. It returns a struct with resolved absolute paths:

  • found — whether a libraries file was located (satk-libraries.json or legacy reuse-libraries.json)
  • enabled — whether custom libraries are configured
  • gatePass — whether the gate is satisfied (can proceed to build)
  • kgIndexPath — absolute path to library-kg/index.md
  • librariesPath — absolute path to the libraries file
  • policyPath — absolute path to block-policy.json
  • dataRoot — absolute path to the directory containing .satk/

Interpret the result:

  • found: false → no custom libraries configured. Proceed with standard Simulink blocks.
  • gatePass: true, found: true → read kgIndexPath for block lookup, then plan and edit.
  • gatePass: false → invoke setup-custom-libraries to populate the Knowledge Index.

Display meaningful description of each check and result instead of stating gate Pass/fail.

No model reading, planning, or editing begins until the gate passes.

Workflow

  1. Ensure Library & Policy Prerequisites: See BLOCKING GATE above. Do not proceed until gates pass.
  2. Library block lookup: List every block type you plan to use, search .satk/library-kg/index.md and the relevant category pages to find each of the library blocks that match.
  3. Read first: Use model_read on the target scope to get block IDs and understand existing topology.
  4. Plan the data flow: For complex edits, sketch inputs → operations → outputs, then map to blocks identified in Step 1 & 2.
  5. Edit: Use model_edit with operations scoped to one subsystem level at a time.
  6. Verify: Use model_read on the scope to confirm the structure matches your intent.
  7. Check connectivity: After all edits in a scope are complete, run model_check to catch unconnected ports or dangling lines. Fix any error-severity issues.

If model_edit returns status: partial: Run both model_read and model_check immediately — don't wait until all edits are complete.

Operation Chaining with ref

Use ref to name a block and #ref to reference it in later operations within the same call:

[{"op": "add_block", "type": "Gain", "name": "MyGain", "ref": "g1"},
 {"op": "connect", "target": "blk_5.y1 -> #g1.u1"}]

In SF scope, #ref references are portless — no .y1/.u1 suffixes (see references/stateflow.md).

The response created map shows ref → blk_id (or ref → sf_X in SF scope). In subsequent calls, use the returned ID — #ref only works within a single call.

Guardrails

  • Never manually construct block path strings from names shown in model_overview or model_read. Block names can contain invisible newlines and trailing whitespace that cause hilite_system, open_system, and get_param to fail. Instead, resolve paths from blk_X IDs:
    % blk_42 → use the number after "blk_" as the SID
    blockPath = Simulink.ID.getFullName('<ModelName>:42');
    hilite_system(blockPath)
    open_system(blockPath)
    get_param(blockPath, 'BlockType')
    
  • Do not call Simulink.BlockDiagram.arrangeSystem or use set_param for block positioning unless the user explicitly requests it. model_edit has a built-in autolayout engine that runs automatically after each call.
  • Always pass layout_mode to model_edit. Use "full" when populating an empty scope (new model root, or a newly-created subsystem) for optimal block arrangement. Use "incremental" when adding blocks to a scope that already has existing blocks (preserves existing positions).
  • Each model_edit call operates in exactly one domain (Simulink, System Composer, or Stateflow) determined by the scope. To add a Chart block and then populate it, use two calls: SL scope for the Chart block, then SF scope for internals. Use model_read between calls to discover the chart's sf_X scope ID.
  • Use meaningfully named variables (e.g., Kp_SpeedController) instead of hardcoded numeric values. Define variables in model workspace or a .m init script.
  • Don't use evaluate_matlab_code with set_param/add_block to bypass model_edit — it skips autolayout, undo tracking, and error recovery
  • Use open_system rather than load_system to open models that are not already open, or when creating new models, unless the user explicitly asks otherwise or the model is a library. This ensures the user can see live edits as they happen.

Naming Conventions

Prefer code-generation-safe names for blocks, signals, and variables:

  • Use only: a-z, A-Z, 0-9, underscore (_)
  • Don't start with a number
  • Don't use leading/trailing or consecutive underscores
  • Prefer names under 32 characters (required for some code generation targets)

Block Types

Use the block's display name in the type field. Do not construct or guess library paths.

  • Custom library blocks (from satk-libraries.json): pass both type AND ReferenceBlock fields. Set type to the block's display name and ReferenceBlock to the full library path from the library KG.

  • Toolbox KB blocks (from activeToolboxes): Use them exactly like custom library blocks — reference the type and ReferenceBlock fields from the toolbox category page in the library KG.

  • Built-in Simulink blocks: Use the BlockType directly: Gain, Sum, Constant, Integrator, SubSystem, Scope

  • Library blocks (Simscape, Aerospace, DSP, Communications, etc.): Use the display name as it appears in the Simulink Library Browser: Voltage Source, Resistor, DC Motor, Solver Configuration, 6DOF (Euler Angles)

  • If model_edit returns INVALID_TYPE: Fall back to the full library path from MATLAB documentation (e.g., ee_lib/Sources/Voltage Source)

[{"op": "add_block", "type": "In", "ReferenceBlock": "customLib_Portsandsubsystems/In", "name": "Voltage", "ref": "v1"},
 {"op": "add_block", "type": "Gain", "ReferenceBlock": "customLib_Mathoperations/Gain", "name": "Kp", "ref": "g1"},
 {"op": "add_block", "type": "Add", "ReferenceBlock": "customLib_Mathoperations/Add", "name": "SumErr", "ref": "s1"},
 {"op": "add_block", "type": "Out", "ReferenceBlock": "customLib_Portsandsubsystems/Out", "name": "Output", "ref": "o1"}]
[{"op": "add_block", "type": "Voltage Source", "name": "V1", "ref": "v1"},
 {"op": "add_block", "type": "Resistor", "name": "R1", "ref": "r1"},
 {"op": "add_block", "type": "Electrical Reference", "name": "Gnd", "ref": "gnd"},
 {"op": "add_block", "type": "Solver Configuration", "name": "Solver", "ref": "sc"}]

Review Gate

After completing all edits for a scope, verify:

  • No error-severity issues from model_check (unconnected ports, dangling lines)
  • All ref names resolved to blk_id in the created map — no dangling #ref references in subsequent calls
  • Stateflow charts pass lint (model_check with checks='["stateflow_lint"]') before layout is applied
  • If model_edit returned status: partial at any point, confirm the scope is now structurally complete via model_read

Domain-Specific Rules

When working with these domains, read the corresponding reference file before editing:

  • Stateflow charts -> references/stateflow.md — model_edit edits chart internals natively. Scope to a chart (sf_X or chart blk_X) and use the same operations: add_block for SF elements, portless connect for transitions, configure for properties. The reference covers SF-specific syntax, scoping, LabelString patterns, and the two-call SL+SF workflow.
  • System Composer architecture models -> references/system-composer.md — Create models with systemcomposer.createModel, then use model_edit. Components use type: "SubSystem", ports use Bus Element blocks. The reference covers component creation, port wiring, and behavior model generation.
  • Simscape physical models -> references/simscape.md — Physical connections use bidirectional <-> syntax. The reference covers connection semantics, port patterns, and initial target variables.

Copyright 2026 The MathWorks, Inc.


리뷰

아직 리뷰가 없습니다. 사용해 본 소감을 남겨 주세요.

댓글

로그인 없이 쓸 수 있습니다. 사용 후기, 질문, 작동하지 않은 환경 등을 편하게 남겨 주세요.

아직 댓글이 없습니다. 첫 댓글을 남겨 보세요.

보내면 바로 공개됩니다. 이메일 주소나 전화번호 같은 개인 정보는 쓰지 마세요. URL은 2개까지입니다.

0 / 1,000자

이 양식은 reCAPTCHA로 보호되며 Google 개인정보처리방침 및 서비스 약관이 적용됩니다.

같은 저장소의 스킬

Author or upgrade Model Advisor checks for Simulink and System Composer models. Covers the full lifecycle: guideline authoring, check specification, Model Advisor check implementation, and qualification testing. Use when creating new checks (edit-time, standard batch, config-parameter, auto-fix), converting legacy StyleOne/StyleTwo/StyleThree checks to modern DetailStyle, creating a guideline for modeling, enforcing a modeling rule, or testing/qualifying a check. Triggers on any modeling constraint (e.g., "blocks shall...", "signals must match...", "parameters shall be set to...").

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

matlab/simulink-agentic-toolkit1.2천2026년 10월 15일 업데이트

Synthesize new waveforms from scratch for Simulink inports using createInputDataset. Use ONLY when the user asks to generate, create, or synthesize signals (step, ramp, sine, chirp, pulse, noise) to populate a Dataset for External Inputs or Signal Editor. Covers timeseries and timetable formats with correct data type, interpolation, units, and dimensions. Also covers function-call and trigger inport timing setup. Do NOT use when the user wants to load, import, or read existing data from files (MAT, CSV, spreadsheet) — even if that data will be used as model input. Do NOT use for running simulations or plotting outputs.

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

matlab/simulink-agentic-toolkit1.2천2026년 10월 15일 업데이트

Common steps for building multi-layer system architecture models using System Composer. Use when implementing architecture models or when interacting with interface dictionaries, allocation sets, stereotypes, and requirements for architecture components.

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

matlab/simulink-agentic-toolkit1.2천2026년 10월 15일 업데이트

Use this skill when the user asks to check Simulink model compliance against a standard (MISRA, MAB, JMAAB, ISO, DO, IEC, EN, CERT C/CWE, AUTOSAR, Simulink Code Inspector (SLCI)), wants to run Model Advisor checks, or needs a compliance report with fix suggestions. For JMAAB/MAB, supplement deterministic checks with agentic review of uncheckable guidelines.

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

matlab/simulink-agentic-toolkit1.2천2026년 10월 15일 업데이트

Guide users through creating and managing .satk/block-policy.json for controlling which blocks the agent can use, which are excluded, and which block parameters the agent should not modify. Use when setting up block usage policy for a project.

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

matlab/simulink-agentic-toolkit1.2천2026년 10월 15일 업데이트

Import data into the Simulation Data Inspector (SDI) from MAT, CSV, or Excel files, from workspace variables, or from a Simulink simulation. Use when the user wants to view a logged file in SDI, load a bench-test log, or verify what a just-completed `Simulink.sdi.createRun` or `sim(model)` produced. Covers the `'file'`, `'vars'`, and `'namevalue'` sources of `createRun`, the auto-populate behavior after `sim()`, and post-import verification. Not for comparing existing runs (use `Simulink.sdi.compareRuns`); not for streaming data live during a running simulation (use `Simulink.sdi.createRunOrAddToStreamedRun` — a separate API); and not for authoring Gherkin or Simulink Test test cases, assertions, or regression tests (use `testing-simulink-models`). Do not activate on test-authoring or verification prompts even when no test-authoring skill is available — say so and stop.

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

matlab/simulink-agentic-toolkit1.2천2026년 10월 15일 업데이트

matlab의 스킬 모두 보기

이 스킬의 문제 신고