本文へ移動
cccskills
無料GitHub で公開

bio-alignment-amplicon-clipping

Trim PCR primers from aligned reads in amplicon-panel BAMs using samtools ampliconclip. Use when processing SARS-CoV-2 ARTIC, hereditary cancer panels, ctDNA hot-spot panels, or any amplicon assay where primer-derived bases would falsely confirm reference at primer footprints.

インストール方法を見る

含まれるファイル(3)

  • SKILL.md8.0 KB
  • examples/ampliconclip_workflow.sh1.7 KB
  • usage-guide.md4.4 KB

SKILL.md(原文)

インストールする前に、エージェントに与えられる指示の中身を確認できます。

Version Compatibility

Reference examples tested with: samtools 1.19+, pysam 0.22+

Before using code patterns, verify installed versions match. If versions differ:

  • Python: pip show <package> then help(module.function) to check signatures
  • CLI: <tool> --version then <tool> --help to confirm flags

If code throws ImportError, AttributeError, or TypeError, introspect the installed package and adapt the example to match the actual API rather than retrying.

Alignment Amplicon Clipping

"Trim primer-derived bases from amplicon BAM" -> Soft- or hard-clip the 5' primer footprint after alignment using a primer BED, then repair fixmate/MD/NM tags.

  • CLI: samtools ampliconclip -b primers.bed input.bam -o clipped.bam (since samtools 1.11)
  • Alternative: iVar trim, BAMClipper, fgbio ClipBam

Why Primer Trimming After Alignment

Amplicon panels (SARS-CoV-2 ARTIC, hereditary cancer panels, ctDNA hot-spot panels, fusion panels, 16S rRNA) use designed PCR primers for enrichment. Primer-derived bases at read 5' ends do NOT reflect biological sequence -- they reflect the primer template. Without trimming:

  • False reference confirmation at primer footprint positions.
  • Variant allele frequency suppressed at variants under primers (the primer sequence cannot capture the variant base).
  • Strand bias artifacts (primers are typically one-strand).

Standard amplicon BAMs should NEVER be processed by samtools markdup -- by design every read at a primer location is a "duplicate" by coordinate. See duplicate-handling for the assay-aware decision.

Tool Selection

ToolWhenNotes
samtools ampliconclipDefault for amplicon panels (since 1.11)Soft- or hard-clip from BED; modifies CIGAR; invalidates MD/NM
iVar trimSARS-CoV-2 ARTIC pipelinesCoordinates by primer name/position; applies hard or soft clip
BAMClipperCapture / hybrid panels with primer overlap5'-end clipping with overlap handling
fgbio ClipBamWhen read-pair coordination mattersSoft/hard-clip with mate-aware end adjustment
cutadapt (pre-alignment)Legacy / when alignment is downstreamTrims at FASTQ stage; less precise for amplicon

Soft-Clip vs Hard-Clip

Goal: Decide whether trimmed bases are kept in the BAM (reversible) or discarded (irreversible).

Approach: Soft-clip is the safe default; hard-clip only when archiving and disk is constrained.

ModeFlagWhat it doesReversible?
Soft-clip(default) / --soft-clipBases kept in SEQ; CIGAR uses S; bases not alignedYes (CIGAR can be re-extended)
Hard-clip--hard-clipBases removed from SEQ; CIGAR uses HNo (bases lost)

Soft-clip is the recommended default. Hard-clip is irreversible -- once applied, the trimmed bases cannot be recovered for re-analysis with different primer coordinates.

Basic ampliconclip Workflow

Goal: Trim primers from a coordinate-sorted, indexed amplicon BAM and produce a downstream-ready BAM.

Approach: Run ampliconclip with primer BED, optionally --both-ends and --strand, then re-fixmate (CIGAR changed) and re-calmd (MD/NM tags invalidated by clip).

# 1. Soft-clip primers (default; reversible)
samtools ampliconclip --both-ends --strand --soft-clip \
    -b primers.bed input.bam -o clipped.bam

# 2. Re-pair tags (CIGARs changed -- mate info needs refresh)
samtools sort -n clipped.bam | \
    samtools fixmate -m - - | \
    samtools sort -o sorted.bam -

# 3. Repair MD/NM tags (invalidated by clip; required by mpileup BAQ and IGV)
samtools calmd -b sorted.bam reference.fa > clipped_final.bam
samtools index clipped_final.bam

Strand-Aware Clipping

--strand clips primer bases only on the strand the primer is designed for. Without --strand, both strands are clipped at the primer site, removing valid biological sequence on the off-strand.

Both-End Clipping

--both-ends allows clipping at both 5' and 3' positions of the read (some primers can appear at either end after alignment). Necessary for amplicon designs where reads can read through the entire amplicon.

Primer BED Format

# tab-separated, 0-based half-open like all BED
chr1   100   125   primer_1_F    +
chr1   500   525   primer_1_R    -
chr1   600   625   primer_2_F    +
chr1   1000  1025  primer_2_R    -

Tools that consume the BED: column 1-3 (region), column 6 (strand) is required for --strand. ARTIC primer schemes ship pre-built BEDs (e.g., primer.bed from artic-network/primer-schemes).

SARS-CoV-2 ARTIC Comparison

ToolApproachWhen
samtools ampliconclipSoft-clip from BED, post-alignmentnf-core/viralrecon, modern ARTIC workflows
iVar trimSoft- or hard-clip with primer-position parsingOriginal ARTIC field bioinformatics

Modern viral consensus pipelines tend to use ampliconclip then samtools consensus --config illumina --ambig for IUPAC heterozygote handling. See reference-operations for consensus generation.

After Clipping: Required Re-Processing

Clipping invalidates several tags and CIGAR-derived fields:

FieldImpactRepair
CIGARNew S or H operations addedAutomatic from ampliconclip
MD:ZMismatch positions now wrongsamtools calmd -b in.bam ref.fa
NM:iEdit distance recomputedsamtools calmd
TLENTemplate length changes when both mates clippedsamtools fixmate -m
ms, MC:ZMate score (lowercase per SAMtags) / mate CIGARsamtools fixmate -m

A clipped BAM that bypasses fixmate + calmd causes silent failures in bcftools mpileup BAQ (which depends on MD), IGV mismatch coloring, and any tool using NM for filtering.

Why Not Markdup

Amplicon reads at primer locations are by design coordinate-degenerate -- every read mapped to the same amplicon shares the same start/end coordinates because they all come from the same primer pair. samtools markdup would mark essentially every read as a duplicate and erase the dataset. For amplicon panels:

  • WITHOUT UMIs: skip dedup entirely; rely on coverage uniformity from amplicon design.
  • WITH UMIs (deep panels): use fgbio GroupReadsByUmi -> CallMolecularConsensusReads instead of markdup. See duplicate-handling.

Common Errors

ErrorCauseSolution
MD tag mismatch after clippingcalmd not runRun samtools calmd -b clipped.bam ref.fa
Variant calls with strand bias at every amplicon endForgot --strandRe-run with strand-aware clipping
Markdup output shows ~100% duplicatesAmplicon BAM was processed with markdupRestart from raw alignment; use ampliconclip; skip markdup
Unexpected reference confirmation at primer-overlapping variantsampliconclip not runRun before variant calling

Quick Reference

TaskCommand
Soft-clip primerssamtools ampliconclip --both-ends --strand -b primers.bed in.bam -o clipped.bam
Hard-clip (irreversible)samtools ampliconclip --both-ends --strand --hard-clip -b primers.bed in.bam -o clipped.bam
Repair MD/NM after clipsamtools calmd -b clipped.bam ref.fa > final.bam
Repair mate infosamtools sort -n - | samtools fixmate -m - - | samtools sort -o out.bam -

Related Skills

  • duplicate-handling - Why amplicon BAMs should not be markdup'd; UMI-aware alternatives
  • alignment-filtering - Post-clip filtering for amplicon variant calling
  • alignment-sorting - Re-sort after fixmate
  • pileup-generation - mpileup flags for amplicon (-aa -A -d 600000 -B)
  • reference-operations - Consensus generation from amplicon BAMs (samtools consensus)
  • read-qc/quality-reports - Pre-alignment adapter/quality trimming

レビュー

まだレビューはありません。使ってみた感想をお寄せください。

同じリポジトリのスキル

概要と使いどころ

Workflow for read alignment, sorting, indexing, mapping statistics, and downstream-ready alignment artifacts.

日本語の概要は準備中です。原文の説明を表示しています。

BioTender-max/awesome-bio-agent-skills2012026年7月2日 更新

alphafold

無料

Validate protein designs using AlphaFold2 structure prediction. Use this skill when: (1) Validating designed sequences fold correctly, (2) Predicting binder-target complex structures, (3) Calculating confidence metrics (pLDDT, pTM, ipTM), (4) Self-consistency validation of designs, (5) Multi-chain complex prediction with AlphaFold-Multimer. For faster single-chain prediction, use esm. For QC thresholds, use protein-qc.

日本語の概要は準備中です。原文の説明を表示しています。

BioTender-max/awesome-bio-agent-skills2012026年7月2日 更新

AlphaFold2 / AlphaFold-Multimer structure prediction for validation and confidence scoring. Use this skill when: (1) Validating designed sequences fold correctly, (2) Predicting binder-target complex structures, (3) Calculating confidence metrics (pLDDT, pTM, ipTM), (4) Self-consistency validation of designs, (5) Multi-chain complex prediction with AlphaFold-Multimer. For faster single-chain prediction, use esm2-sequence-scoring. For QC thresholds, use protein-design-qc.

日本語の概要は準備中です。原文の説明を表示しています。

BioTender-max/awesome-bio-agent-skills2012026年7月2日 更新

Workflow for event-level and isoform-level splicing analysis with sashimi-ready outputs and splice QC.

日本語の概要は準備中です。原文の説明を表示しています。

BioTender-max/awesome-bio-agent-skills2012026年7月2日 更新

atac-seq

無料

ATAC-seq processing with assay QC, MACS3 peak calling, consensus peak matrices, differential accessibility, and motif or footprint follow-up.

日本語の概要は準備中です。原文の説明を表示しています。

BioTender-max/awesome-bio-agent-skills2012026年7月2日 更新

bindcraft

無料

End-to-end binder design using BindCraft hallucination. Use this skill when: (1) Designing protein binders with built-in AF2 validation, (2) Running production-quality binder campaigns, (3) Using different design protocols (fast, default, slow), (4) Need joint backbone and sequence optimization, (5) Want high experimental success rate. For backbone-only generation, use rfdiffusion. For QC thresholds, use protein-qc. For tool selection guidance, use binder-design.

日本語の概要は準備中です。原文の説明を表示しています。

BioTender-max/awesome-bio-agent-skills2012026年7月2日 更新

BioTender-max のスキルをすべて見る

このスキルの問題を報告する