本文へ移動
cccskills
無料GitHub で公開

convergence-test

Use when the user asks to test ENCUT convergence, k-point convergence, or any parameter sweep to determine converged computational settings.

日本語の概要は準備中です。原文の説明を表示しています。

Hello-QM/catgo-LRGスター 208(GitHub 208 + cccskills 0)

実行スコア 未検証

インストール方法を見る

含まれるファイル(1)

  • SKILL.md5.6 KB

SKILL.md(原文)

インストールする前に、エージェントに与えられる指示の中身を確認できます。

Convergence Testing

Purpose

Before production calculations, verify that results are converged with respect to key numerical parameters. The two most important are:

  1. ENCUT (planewave cutoff energy) -- controls basis set completeness
  2. KPOINTS (k-point mesh density) -- controls Brillouin zone sampling

Convergence is reached when the target property (energy, forces, band gap) changes by less than a threshold (typically 1 meV/atom for energy).

Fan-Out Pattern

Convergence tests use a fan-out DAG: one input structure feeds into multiple independent single_point calculations with different parameter values.

                   +--> single_point(ENCUT=300)
                   |
structure_input ---+--> single_point(ENCUT=400)
                   |
                   +--> single_point(ENCUT=500)
                   |
                   +--> single_point(ENCUT=600)
                   |
                   +--> single_point(ENCUT=700)

Use single_point (not geo_opt) to isolate the parameter effect without geometry changes confounding the comparison.

MCP Workflow: ENCUT Convergence

Step 1: Create workflow

{"tool": "catgo_workflow_engine", "arguments": {
  "action": "create", "name": "ENCUT convergence - TiO2"
}}

Step 2: Add single_point tasks at each ENCUT

{"tool": "catgo_workflow_engine", "arguments": {
  "action": "add_task", "workflow_id": "wf_conv",
  "task_type": "single_point",
  "params": {"software": "vasp", "ENCUT": 300, "system_name": "ENCUT=300"}
}}
{"tool": "catgo_workflow_engine", "arguments": {
  "action": "add_task", "workflow_id": "wf_conv",
  "task_type": "single_point",
  "params": {"software": "vasp", "ENCUT": 400, "system_name": "ENCUT=400"}
}}
{"tool": "catgo_workflow_engine", "arguments": {
  "action": "add_task", "workflow_id": "wf_conv",
  "task_type": "single_point",
  "params": {"software": "vasp", "ENCUT": 500, "system_name": "ENCUT=500"}
}}

Repeat for ENCUT = 600, 700, 800.

Step 3: Submit

{"tool": "catgo_workflow_engine", "arguments": {
  "action": "submit", "workflow_id": "wf_conv"
}}

Step 4: Check results

{"tool": "catgo_workflow_engine", "arguments": {
  "action": "get_result", "workflow_id": "wf_conv", "task_id": "task_encut300"
}}
{"tool": "catgo_analyze", "arguments": {
  "action": "convergence", "workflow_id": "wf_conv"
}}

MCP Workflow: KPOINTS Convergence

{"tool": "catgo_workflow_engine", "arguments": {
  "action": "add_task", "workflow_id": "wf_conv",
  "task_type": "single_point",
  "params": {"software": "vasp", "ENCUT": 520, "KPOINTS": [2,2,1],
             "system_name": "2x2x1"}
}}
{"tool": "catgo_workflow_engine", "arguments": {
  "action": "add_task", "workflow_id": "wf_conv",
  "task_type": "single_point",
  "params": {"software": "vasp", "ENCUT": 520, "KPOINTS": [4,4,1],
             "system_name": "4x4x1"}
}}

Repeat for 6x6x1, 8x8x1. Use the converged ENCUT from the previous test.

Python API

ENCUT Convergence

from catgo.workflow import Workflow

wf = Workflow("ENCUT convergence - TiO2")
inp = wf.add_task("structure_input", structure=tio2_json)

encut_values = [300, 400, 500, 600, 700, 800]
tasks = {}
for encut in encut_values:
    tasks[encut] = wf.add_task("single_point",
        structure=inp.output.structure,
        software="vasp", ENCUT=encut,
        system_name=f"ENCUT={encut}")

wf.submit()

KPOINTS Convergence

wf = Workflow("KPOINTS convergence - TiO2 slab")
inp = wf.add_task("structure_input", structure=tio2_slab_json)

kpoints_list = [[2,2,1], [4,4,1], [6,6,1], [8,8,1], [10,10,1]]
for kp in kpoints_list:
    label = f"{kp[0]}x{kp[1]}x{kp[2]}"
    wf.add_task("single_point",
        structure=inp.output.structure,
        software="vasp", ENCUT=520, KPOINTS=kp,
        system_name=label)

wf.submit()

Convergence Criteria

PropertyThresholdTypical Converged ENCUT
Total energy1 meV/atom1.3x max(ENMAX) in POTCAR
Forces5 meV/ASame as energy
Band gap10 meVMay need higher ENCUT
Stress tensor0.1 kbarOften needs 1.5x ENMAX

Recommended ENCUT Values by Element Type

SystemStarting ENCUT RangeNotes
Simple metals (Cu, Pt)300-500Usually converges quickly
Oxides (TiO2, RuO2)400-600O has high ENMAX
Nitrides, carbides400-600N, C have moderate ENMAX
F-containing500-800F has very high ENMAX

Two-Stage Strategy

  1. ENCUT first: Fix KPOINTS at a moderate value (e.g., 4x4x4), sweep ENCUT. Pick the converged ENCUT.
  2. KPOINTS second: Fix ENCUT at converged value, sweep KPOINTS. Pick the converged mesh.

This avoids the combinatorial explosion of testing all ENCUT x KPOINTS pairs.

Common Pitfalls

  1. Always use single_point, not geo_opt. Geometry changes at different ENCUT introduce noise that masks the convergence behavior.
  2. For slab models, only converge the in-plane k-points (e.g., NxNx1). The vacuum direction needs only 1 k-point.
  3. ENCUT should be at least 1.3x the maximum ENMAX in the POTCAR. Check POTCAR ENMAX values before choosing the test range.
  4. Report energy per atom (E_total / N_atoms), not total energy, for meaningful comparison across different systems.
  5. Always plot E vs parameter -- convergence should be monotonic. Non-monotonic behavior suggests other issues (e.g., SCF convergence).

レビュー

まだレビューはありません。使ってみた感想をお寄せください。

コメント

ログインなしで書き込めます。使ってみた感想、質問、動かなかった環境などを気軽にどうぞ。

まだコメントはありません。最初のコメントを書いてみませんか。

送信するとすぐに公開されます。メールアドレスや電話番号などの個人情報は書かないでください。URL は 2 つまでです。

0 / 1000 文字

このフォームは reCAPTCHA で保護されており、Google のプライバシーポリシーと利用規約が適用されます。

同じリポジトリのスキル

abinit

無料

Generate and manage ABINIT DFT calculations. Use when the user requests ABINIT, or needs DFPT phonons, GW calculations, or BSE optical spectra.

日本語の概要は準備中です。原文の説明を表示しています。

Hello-QM/catgo-LRG2082026年10月23日 更新

Use when the user asks to place an adsorbate molecule on a surface, find adsorption sites, or set up a surface+adsorbate model for DFT.

日本語の概要は準備中です。原文の説明を表示しています。

Hello-QM/catgo-LRG2082026年10月23日 更新

Use when the user asks for adsorption energy, binding energy, or wants to compare how strongly a molecule binds to a surface.

日本語の概要は準備中です。原文の説明を表示しています。

Hello-QM/catgo-LRG2082026年10月23日 更新

Use when the user asks to analyze computational results: Gibbs free energy, OER/HER/CO2RR overpotentials, adsorption energy, convergence tests, DOS/d-band analysis, or Bader charge analysis.

日本語の概要は準備中です。原文の説明を表示しています。

Hello-QM/catgo-LRG2082026年10月23日 更新

Use AmberTools antechamber for molecular force field parameterization. Generates GAFF/GAFF2 parameters and AM1-BCC or RESP charges for use in AMBER or LAMMPS classical MD simulations.

日本語の概要は準備中です。原文の説明を表示しています。

Hello-QM/catgo-LRG2082026年10月23日 更新

atom-ops

無料

One-shot recipes for adding, deleting, moving, and replacing individual atoms in the active CatGo viewer structure. Use whenever the user asks to "add an atom", "delete atoms", "remove this atom", "move atom N", "replace H with Li", or any single-atom edit — including "add a hydrogen on top of atom 12" / "delete atoms 5–9" / "swap the oxygen at site 3 for fluorine". Skips the discovery loop (no need to list structure tools or check adsorption sites first); goes straight to the matching `catgo_structure` action. Triggers in Chinese on 加原子, 删原子, 减原子, 移动原子, 替换原子, 增加氢, 删除氧, 把 ... 换成 ....

日本語の概要は準備中です。原文の説明を表示しています。

Hello-QM/catgo-LRG2082026年10月23日 更新

Hello-QM のスキルをすべて見る

このスキルの問題を報告する