跳到正文
cccskills
免费在 GitHub 公开

endo-bolus-calculator-use-encourage

Suggests encouraging patients to use appropriately adjusted embedded bolus calculators in CSII and to provide education regarding their use and limitations. Triggers include: 'Patient starting pump, discuss bolus calculator', 'Review bolus calculator education at pump initiation'.

中文简介正在准备中。当前显示原文说明。

实测评分 未实测

查看安装方法

包含的文件(1)

  • SKILL.md2.7 KB

SKILL.md(原文)

安装前可以查看交给 AI 代理的指令内容。

Encourage use of appropriately adjusted embedded bolus calculators

STEP 1 — Gather Information

Collect patient's current insulin-to-carbohydrate ratio, correction factor (insulin sensitivity), glucose target, active insulin time, carbohydrate counting proficiency, recent glucose logs, pump model and embedded calculator availability, and any history of hypoglycemia or hyperglycemia postprandial.

STEP 2 — Rule In / Rule Out

Determine if the patient is using CSII with rapid-acting analog insulin and has an embedded bolus calculator available; if yes, proceed to stratification, if no, consider alternative bolus calculation methods or defer calculator use.

STEP 3 — Classify or Stratify

Stratify by patient's experience with bolus calculators: novice (never used) vs experienced (previously used but may need adjustment) to tailor education approach.

STEP 4 — Decide

For novice patients, provide structured education on how to input carb ratios, correction factors, and active insulin time, and encourage use of the embedded calculator for all boluses; for experienced patients, review and adjust settings based on recent glucose trends and reinforce education on limitations.

Clinical Guardrails / Mimics / Pitfalls

Do not rely solely on the calculator for meals high in fat or protein without considering extended bolus features; avoid using outdated carb ratios; do not ignore active insulin time leading to insulin stacking; ensure patient understands that the calculator does not replace glucose monitoring.

Concrete Clinical Example

A 24-year-old with T1DM starting CSII with insulin aspart reports carbohydrate counting ability but uncertain about bolus amounts. Clinician gathers current ICR 1:10 g, correction factor 1:50 mg/dL, target 120 mg/dL, active insulin time 4 hours. Patient is novice with embedded calculator. Clinician provides education on entering these values into the pump's bolus wizard, demonstrates a test bolus for 30g carbs, and advises to use calculator for all meal and correction boluses while checking postprandial glucose.

Source: Diabetes Technology—Continuous Subcutaneous Insulin Infusion Therapy and Continuous Glucose Monitoring in Adults, Endocrine Society, 2016, doi:10.1210/jc.2016-2534

TODO: consider adding scripts/calc.py for the endo-bolus-calculator-use-encourage calculator

评价

还没有评价。欢迎分享你的使用感受。

评论

无需登录即可发表。欢迎分享使用感受、提问,或说明在哪些环境下无法运行。

还没有评论。来写第一条吧。

提交后会立即公开。请勿填写邮箱、电话等个人信息。URL 最多 2 个。

0 / 1000 字

此表单受 reCAPTCHA 保护,适用 Google 的隐私权政策和服务条款。

同一仓库的技能

Guide pump setting adjustments for the MiniMed 780G system based on CareLink data, using Medtronic's 3-step follow-up workflow. Use when a clinician has CareLink data for a 780G patient and wants to know what to change — which setting, by how much, and how to program it. Triggers include: "what do I adjust", "how to fix high TIR", "how to reduce hypos", "adjust ICR/ISF/basal", "SmartGuard settings", "780G pump settings review", or any question about optimising 780G therapy after reviewing a download.

中文简介正在准备中。当前显示原文说明。

dromlakhani/MD2SKILL142026年10月20日 更新

Performs corticotropin stimulation test to diagnose adrenal insufficiency when morning cortisol is indeterminate (3-15 µg/dL). Triggers include morning cortisol 3-15 µg/dL requiring further AI testing.

中文简介正在准备中。当前显示原文说明。

dromlakhani/MD2SKILL142026年10月20日 更新

Administers immediate parenteral injection of 50–100 mg hydrocortisone for suspected adrenal crisis secondary to adrenal insufficiency. Triggers include hypotension, hypoglycemia, or acute illness in a patient with known adrenal insufficiency.

中文简介正在准备中。当前显示原文说明。

dromlakhani/MD2SKILL142026年10月20日 更新

Clinicians educate adrenal insufficiency patients taking nondexamethasone glucocorticoids who initiate enzyme-inducing antiepileptic drugs about early signs of adrenal insufficiency. Trigger when an AI patient on nondexamethasone GC starts an enzyme-inducing AED such as phenytoin, carbamazepine, or oxcarbazepine.

中文简介正在准备中。当前显示原文说明。

dromlakhani/MD2SKILL142026年10月20日 更新

In central hypothyroidism patients receiving levothyroxine who initiate enzyme‑inducing antiepileptic drugs, the guideline recommends checking free T4 at least 6 weeks after AED start and increasing the levothyroxine dose if free T4 falls below the target range. Triggers include: central hypothyroidism patient on levothyroxine starting antiepileptic drug such as phenytoin, carbamazepine, or oxcarbazepine.

中文简介正在准备中。当前显示原文说明。

dromlakhani/MD2SKILL142026年10月20日 更新

Applies serum cortisol cutoffs (<3 μg/dL indicates central adrenal insufficiency; >15 μg/dL likely excludes it) when evaluating morning cortisol for suspected adrenal insufficiency. Triggers include morning cortisol measurement in suspected AI and use when interpreting morning cortisol levels for adrenal insufficiency workup.

中文简介正在准备中。当前显示原文说明。

dromlakhani/MD2SKILL142026年10月20日 更新

查看 dromlakhani 的全部技能

报告此技能的问题