跳到正文
cccskills
免费在 GitHub 公开

es-cgm-vs-smbg-t1d-mdi

Recommends CGM over SMBG for type 1 diabetes patients on multiple daily injections to reduce hypoglycemia risk. Triggered by clinician questions such as "Should I use CGM or SMBG for this T1D patient on MDI?" or "Is CGM preferred for glucose monitoring in this patient?"

中文简介正在准备中。当前显示原文说明。

实测评分 未实测

查看安装方法

包含的文件(1)

  • SKILL.md2.6 KB

SKILL.md(原文)

安装前可以查看交给 AI 代理的指令内容。

CGM vs SMBG for Type 1 Diabetes on MDI

STEP 1 — Gather Information

Confirm type 1 diabetes diagnosis and current multiple daily injection (MDI) regimen; assess hypoglycemia history (frequency, severity, nocturnal events), hypoglycemia awareness, patient’s ability/willingness to use CGM (dexterity, visual/hearing for alerts), insurance coverage/access, and need for structured education on device use and data interpretation.

STEP 2 — Rule In / Rule Out

Rule out CGM if the patient cannot safely operate the device (e.g., severe dexterity impairment, uncontrolled dermatitis, lack of training resources, or explicit refusal); otherwise rule in for CGM consideration.

STEP 3 — Classify or Stratify

Stratify by hypoglycemia risk: high (history of severe hypoglycemia requiring assistance, hypoglycemia unawareness, frequent nocturnal events) versus moderate (no severe events but suboptimal glycemic control); prioritize CGM for high‑risk patients.

STEP 4 — Decide

Recommend initiating real‑time CGM (or intermittently scanned CGM with predictive alerts) rather than SMBG alone; provide structured education on device use, troubleshooting, and data interpretation; retain access to SMBG for calibration/validation and sensor warm‑up periods.

Clinical Guardrails / Mimics / Pitfalls

Do not rely solely on CGM values for insulin dosing without confirmatory SMBG during sensor warm‑up, when symptoms mismatch sensor readings, or if sensor malfunctions; do not omit structured education; do not use CGM in patients with substances that interfere with sensor accuracy (e.g., high‑dose vitamin C, hydroxyurea) without verification; do not assume CGM eliminates the need for SMBG entirely.

Concrete Clinical Example

A 22‑year‑old college student with T1D on MDI (glargine basal, lispro bolus) reports two nocturnal hypoglycemia episodes requiring assistance in the past month and fears hypoglycemia disrupting sleep; after confirming MDI regimen and hypoglycemia risk, CGM is initiated with education, and SMBG is retained for calibration and symptom‑sensor mismatches.

Source: Management of Individuals With Diabetes at High Risk for Hypoglycemia: An Endocrine Society Clinical Practice Guideline, Endocrine Society, 2023, https://doi.org/10.1210/clinem/dgac596

评价

还没有评价。欢迎分享你的使用感受。

评论

无需登录即可发表。欢迎分享使用感受、提问,或说明在哪些环境下无法运行。

还没有评论。来写第一条吧。

提交后会立即公开。请勿填写邮箱、电话等个人信息。URL 最多 2 个。

0 / 1000 字

此表单受 reCAPTCHA 保护,适用 Google 的隐私权政策和服务条款。

同一仓库的技能

Guide pump setting adjustments for the MiniMed 780G system based on CareLink data, using Medtronic's 3-step follow-up workflow. Use when a clinician has CareLink data for a 780G patient and wants to know what to change — which setting, by how much, and how to program it. Triggers include: "what do I adjust", "how to fix high TIR", "how to reduce hypos", "adjust ICR/ISF/basal", "SmartGuard settings", "780G pump settings review", or any question about optimising 780G therapy after reviewing a download.

中文简介正在准备中。当前显示原文说明。

dromlakhani/MD2SKILL142026年10月20日 更新

Performs corticotropin stimulation test to diagnose adrenal insufficiency when morning cortisol is indeterminate (3-15 µg/dL). Triggers include morning cortisol 3-15 µg/dL requiring further AI testing.

中文简介正在准备中。当前显示原文说明。

dromlakhani/MD2SKILL142026年10月20日 更新

Administers immediate parenteral injection of 50–100 mg hydrocortisone for suspected adrenal crisis secondary to adrenal insufficiency. Triggers include hypotension, hypoglycemia, or acute illness in a patient with known adrenal insufficiency.

中文简介正在准备中。当前显示原文说明。

dromlakhani/MD2SKILL142026年10月20日 更新

Clinicians educate adrenal insufficiency patients taking nondexamethasone glucocorticoids who initiate enzyme-inducing antiepileptic drugs about early signs of adrenal insufficiency. Trigger when an AI patient on nondexamethasone GC starts an enzyme-inducing AED such as phenytoin, carbamazepine, or oxcarbazepine.

中文简介正在准备中。当前显示原文说明。

dromlakhani/MD2SKILL142026年10月20日 更新

In central hypothyroidism patients receiving levothyroxine who initiate enzyme‑inducing antiepileptic drugs, the guideline recommends checking free T4 at least 6 weeks after AED start and increasing the levothyroxine dose if free T4 falls below the target range. Triggers include: central hypothyroidism patient on levothyroxine starting antiepileptic drug such as phenytoin, carbamazepine, or oxcarbazepine.

中文简介正在准备中。当前显示原文说明。

dromlakhani/MD2SKILL142026年10月20日 更新

Applies serum cortisol cutoffs (<3 μg/dL indicates central adrenal insufficiency; >15 μg/dL likely excludes it) when evaluating morning cortisol for suspected adrenal insufficiency. Triggers include morning cortisol measurement in suspected AI and use when interpreting morning cortisol levels for adrenal insufficiency workup.

中文简介正在准备中。当前显示原文说明。

dromlakhani/MD2SKILL142026年10月20日 更新

查看 dromlakhani 的全部技能

报告此技能的问题