Configures Simulink simulations non-destructively using SimulationInput objects — parameter overrides without modifying the model, batch sweeps via parsim, custom input signals via Dataset, and simulation data retrieval via logsout. Use when running sim()/parsim() with setVariable, setBlockParameter, setExternalInput, or when performing parameter sweeps and multi-run analysis. Not needed for one-shot simulations without configuration.

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

설치 방법 보기

포함된 파일(2)

  • SKILL.md5.6 KB
  • manifest.yaml650 B

SKILL.md(원문)

설치하기 전에 에이전트에게 전달되는 지시 내용을 확인할 수 있습니다.

Simulating Simulink Models with the sim Command

Use this skill when you need to configure a simulation non-destructively — parameter overrides, custom inputs, batch execution, or structured output access. For persistent, reusable pass/fail behavioral testing (especially of individual subsystems), use testing-simulink-models instead. For trivial one-shot simulations without configuration, a direct sim() call suffices without this skill.

When to Use

  • Overriding model or block parameters non-destructively (setVariable, setBlockParameter, setModelParameter) — without modifying the .slx file
  • Passing custom input signals to root-level Inport blocks via setExternalInput with a Dataset
  • Running parameter sweeps or batch simulations (SimulationInput arrays, parsim, Fast Restart)
  • Accessing logged signal data (logsout) for analysis after simulation

When NOT to Use

  • Trivial one-shot simulations without parameter overrides or custom inputs — a direct sim('ModelName') call works without this skill
  • Writing declarative Gherkin-based tests → use testing-simulink-models
  • Testing an individual subsystem or component → use testing-simulink-models (requires Simulink Test; auto-creates a harness, compiles only the subsystem — much faster than sim() which always compiles the entire model)
  • Adding, connecting, or deleting blocks → use building-simulink-models
  • Checking model structure for unconnected ports → use model_check tool directly
  • Generating requirements from model behavior → use generate-requirement-drafts

Minimal working pattern

Always simulate using Simulink.SimulationInput and Simulink.SimulationOutput:

in = Simulink.SimulationInput('MyModel');
in = in.setModelParameter('StopTime', '10');
out = sim(in);

Setting parameters

Use SimulationInput methods to configure the simulation:

% Model-level parameters (StopTime, SolverType, SimulationMode, etc.)
in = in.setModelParameter('StopTime', '10', 'SolverType', 'Fixed-step');

% Block parameters — resolve path from blk_X ID (never type block names manually)
blkPath = Simulink.ID.getFullName('MyModel:5');
in = in.setBlockParameter(blkPath, 'Gain', '5');

% MATLAB workspace variables used by the model
in = in.setVariable('Kp', 1.2);

Input signals

Pass input signals through Inport blocks using a Simulink.SimulationData.Dataset. Elements are matched to Inport blocks by index position — the first element maps to the Inport with port number 1, the second to port number 2, and so on.

dt = 0.01;
N = 1000;
t = dt*(0:N)';
u = sin(2*pi*t);

ts = timeseries(u, t);

ds = Simulink.SimulationData.Dataset;
ds{1} = ts;

in = in.setExternalInput(ds);
out = sim(in);

You can also use timetable as an input format:

secs = seconds(t);
tt = timetable(secs, u);

ds = Simulink.SimulationData.Dataset;
ds{1} = tt;

in = in.setExternalInput(ds);

Discovering logged data

First, discover what kinds of logged data the model produces using who, then inspect signal names within logsout:

in = Simulink.SimulationInput('MyModel');
out = sim(in);

% See what logging properties exist (logsout, yout, tout, etc.)
who(out)

% List individual signal names within logsout
disp(out.logsout.getElementNames);

Accessing logged data

Logged signals are available through out.logsout. Access them directly by name:

% Plot a logged signal
plot(out.logsout.get('signalName').Values)

% Get time and data separately
sig = out.logsout.get('signalName').Values;
plot(sig.Time, sig.Data)

Multiple simulations

When running many simulations, create an array of Simulink.SimulationInput objects:

in = repmat(Simulink.SimulationInput('MyModel'),N,1);
for k = 1:N
    in(k) = Simulink.SimulationInput('MyModel');
    in(k) = in(k).setVariable('gain', gains(k));
end
out = sim(in);

To enable fast restart for iterative sweeps (compiles the model only once):

out = sim(in, 'UseFastRestart', 'on');

Parallel simulation (parsim)

To run multiple simulations in parallel, use parsim instead of looping over sim:

for k = 1:N
    in(k) = Simulink.SimulationInput('MyModel');
    in(k) = in(k).setVariable('gain', gains(k));
end
out = parsim(in);

parsim also supports 'UseFastRestart','on' for faster batch runs.

Guardrails

  • Never use set_param, load_system, or open_system to drive simulation — SimulationInput replaces all of these.
  • Never wrap SimulationOutput access in try-catch or isfield — sim either returns a valid object or throws. SimulationOutput has no isfield method.
  • Never create unnecessary intermediate variables for logged data — access directly via out.logsout.get('name').Values.
  • Always use in/out as variable names for SimulationInput/SimulationOutput.
  • Always use setExternalInput with a Dataset — don't pass comma-separated lists of variables.

Copyright 2026 The MathWorks, Inc.


리뷰

아직 리뷰가 없습니다. 사용해 본 소감을 남겨 주세요.

댓글

로그인 없이 쓸 수 있습니다. 사용 후기, 질문, 작동하지 않은 환경 등을 편하게 남겨 주세요.

아직 댓글이 없습니다. 첫 댓글을 남겨 보세요.

보내면 바로 공개됩니다. 이메일 주소나 전화번호 같은 개인 정보는 쓰지 마세요. URL은 2개까지입니다.

0 / 1,000자

이 양식은 reCAPTCHA로 보호되며 Google 개인정보처리방침 및 서비스 약관이 적용됩니다.

같은 저장소의 스킬

Author or upgrade Model Advisor checks for Simulink and System Composer models. Covers the full lifecycle: guideline authoring, check specification, Model Advisor check implementation, and qualification testing. Use when creating new checks (edit-time, standard batch, config-parameter, auto-fix), converting legacy StyleOne/StyleTwo/StyleThree checks to modern DetailStyle, creating a guideline for modeling, enforcing a modeling rule, or testing/qualifying a check. Triggers on any modeling constraint (e.g., "blocks shall...", "signals must match...", "parameters shall be set to...").

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

matlab/simulink-agentic-toolkit1.2천2026년 10월 15일 업데이트

Synthesize new waveforms from scratch for Simulink inports using createInputDataset. Use ONLY when the user asks to generate, create, or synthesize signals (step, ramp, sine, chirp, pulse, noise) to populate a Dataset for External Inputs or Signal Editor. Covers timeseries and timetable formats with correct data type, interpolation, units, and dimensions. Also covers function-call and trigger inport timing setup. Do NOT use when the user wants to load, import, or read existing data from files (MAT, CSV, spreadsheet) — even if that data will be used as model input. Do NOT use for running simulations or plotting outputs.

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

matlab/simulink-agentic-toolkit1.2천2026년 10월 15일 업데이트

Common steps for building multi-layer system architecture models using System Composer. Use when implementing architecture models or when interacting with interface dictionaries, allocation sets, stereotypes, and requirements for architecture components.

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

matlab/simulink-agentic-toolkit1.2천2026년 10월 15일 업데이트

Builds and edits Simulink, System Composer, Stateflow, and Simscape models. Use when modifying model structure, parameters, ports, connections, or Stateflow chart internals.

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

matlab/simulink-agentic-toolkit1.2천2026년 10월 15일 업데이트

Use this skill when the user asks to check Simulink model compliance against a standard (MISRA, MAB, JMAAB, ISO, DO, IEC, EN, CERT C/CWE, AUTOSAR, Simulink Code Inspector (SLCI)), wants to run Model Advisor checks, or needs a compliance report with fix suggestions. For JMAAB/MAB, supplement deterministic checks with agentic review of uncheckable guidelines.

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

matlab/simulink-agentic-toolkit1.2천2026년 10월 15일 업데이트

Guide users through creating and managing .satk/block-policy.json for controlling which blocks the agent can use, which are excluded, and which block parameters the agent should not modify. Use when setting up block usage policy for a project.

한국어 요약은 준비 중입니다. 원문 설명을 표시하고 있습니다.

matlab/simulink-agentic-toolkit1.2천2026년 10월 15일 업데이트

matlab의 스킬 모두 보기

이 스킬의 문제 신고