Testing patterns for PHPUnit and Playwright E2E tests. Use when writing tests, debugging test failures, setting up test coverage, or implementing test patterns for ActivityPub features.
日本語の概要は準備中です。原文の説明を表示しています。
Lab automation platform for Flex/OT-2 robots. Write Protocol API v2 protocols, liquid handling, hardware modules (heater-shaker, thermocycler), labware management, for automated pipetting workflows.
インストールする前に、エージェントに与えられる指示の中身を確認できます。
Opentrons is a Python-based lab automation platform for Flex and OT-2 robots. Write Protocol API v2 protocols for liquid handling, control hardware modules (heater-shaker, thermocycler), manage labware, for automated pipetting workflows.
This skill should be used when:
Every Opentrons protocol follows a standard structure:
from opentrons import protocol_api
# Metadata
metadata = {
'protocolName': 'My Protocol',
'author': 'Name <email@example.com>',
'description': 'Protocol description',
'apiLevel': '2.19' # Use latest available API version
}
# Requirements (optional)
requirements = {
'robotType': 'Flex', # or 'OT-2'
'apiLevel': '2.19'
}
# Run function
def run(protocol: protocol_api.ProtocolContext):
# Protocol commands go here
pass
Key elements:
protocol_api from opentronsmetadata dict with protocolName, author, description, apiLevelrequirements dict for robot type and API versionrun() function receiving ProtocolContext as parameterrun() functionLoading Instruments (Pipettes):
def run(protocol: protocol_api.ProtocolContext):
# Load pipette on specific mount
left_pipette = protocol.load_instrument(
'p1000_single_flex', # Instrument name
'left', # Mount: 'left' or 'right'
tip_racks=[tip_rack] # List of tip rack labware objects
)
Common pipette names:
p50_single_flex, p1000_single_flex, p50_multi_flex, p1000_multi_flexp20_single_gen2, p300_single_gen2, p1000_single_gen2, p20_multi_gen2, p300_multi_gen2Loading Labware:
# Load labware directly on deck
plate = protocol.load_labware(
'corning_96_wellplate_360ul_flat', # Labware API name
'D1', # Deck slot (Flex: A1-D3, OT-2: 1-11)
label='Sample Plate' # Optional display label
)
# Load tip rack
tip_rack = protocol.load_labware('opentrons_flex_96_tiprack_1000ul', 'C1')
# Load labware on adapter
adapter = protocol.load_adapter('opentrons_flex_96_tiprack_adapter', 'B1')
tips = adapter.load_labware('opentrons_flex_96_tiprack_200ul')
Loading Modules:
# Temperature module
temp_module = protocol.load_module('temperature module gen2', 'D3')
temp_plate = temp_module.load_labware('corning_96_wellplate_360ul_flat')
# Magnetic module
mag_module = protocol.load_module('magnetic module gen2', 'C2')
mag_plate = mag_module.load_labware('nest_96_wellplate_100ul_pcr_full_skirt')
# Heater-Shaker module
hs_module = protocol.load_module('heaterShakerModuleV1', 'D1')
hs_plate = hs_module.load_labware('corning_96_wellplate_360ul_flat')
# Thermocycler module (takes up specific slots automatically)
tc_module = protocol.load_module('thermocyclerModuleV2')
tc_plate = tc_module.load_labware('nest_96_wellplate_100ul_pcr_full_skirt')
Basic Operations:
# Pick up tip
pipette.pick_up_tip()
# Aspirate (draw liquid in)
pipette.aspirate(
volume=100, # Volume in µL
location=source['A1'] # Well or location object
)
# Dispense (expel liquid)
pipette.dispense(
volume=100,
location=dest['B1']
)
# Drop tip
pipette.drop_tip()
# Return tip to rack
pipette.return_tip()
Complex Operations:
# Transfer (combines pick_up, aspirate, dispense, drop_tip)
pipette.transfer(
volume=100,
source=source_plate['A1'],
dest=dest_plate['B1'],
new_tip='always' # 'always', 'once', or 'never'
)
# Distribute (one source to multiple destinations)
pipette.distribute(
volume=50,
source=reservoir['A1'],
dest=[plate['A1'], plate['A2'], plate['A3']],
new_tip='once'
)
# Consolidate (multiple sources to one destination)
pipette.consolidate(
volume=50,
source=[plate['A1'], plate['A2'], plate['A3']],
dest=reservoir['A1'],
new_tip='once'
)
Advanced Techniques:
# Mix (aspirate and dispense in same location)
pipette.mix(
repetitions=3,
volume=50,
location=plate['A1']
)
# Air gap (prevent dripping)
pipette.aspirate(100, source['A1'])
pipette.air_gap(20) # 20µL air gap
pipette.dispense(120, dest['A1'])
# Blow out (expel remaining liquid)
pipette.blow_out(location=dest['A1'].top())
# Touch tip (remove droplets on tip exterior)
pipette.touch_tip(location=plate['A1'])
Flow Rate Control:
# Set flow rates (µL/s)
pipette.flow_rate.aspirate = 150
pipette.flow_rate.dispense = 300
pipette.flow_rate.blow_out = 400
Well Access Methods:
# By name
well_a1 = plate['A1']
# By index
first_well = plate.wells()[0]
# All wells
all_wells = plate.wells() # Returns list
# By rows
rows = plate.rows() # Returns list of lists
row_a = plate.rows()[0] # All wells in row A
# By columns
columns = plate.columns() # Returns list of lists
column_1 = plate.columns()[0] # All wells in column 1
# Wells by name (dictionary)
wells_dict = plate.wells_by_name() # {'A1': Well, 'A2': Well, ...}
Location Methods:
# Top of well (default: 1mm below top)
pipette.aspirate(100, well.top())
pipette.aspirate(100, well.top(z=5)) # 5mm above top
# Bottom of well (default: 1mm above bottom)
pipette.aspirate(100, well.bottom())
pipette.aspirate(100, well.bottom(z=2)) # 2mm above bottom
# Center of well
pipette.aspirate(100, well.center())
Temperature Module:
# Set temperature
temp_module.set_temperature(celsius=4)
# Wait for temperature
temp_module.await_temperature(celsius=4)
# Deactivate
temp_module.deactivate()
# Check status
current_temp = temp_module.temperature # Current temperature
target_temp = temp_module.target # Target temperature
Magnetic Module:
# Engage (raise magnets)
mag_module.engage(height_from_base=10) # mm from labware base
# Disengage (lower magnets)
mag_module.disengage()
# Check status
is_engaged = mag_module.status # 'engaged' or 'disengaged'
Heater-Shaker Module:
# Set temperature
hs_module.set_target_temperature(celsius=37)
# Wait for temperature
hs_module.wait_for_temperature()
# Set shake speed
hs_module.set_and_wait_for_shake_speed(rpm=500)
# Close labware latch
hs_module.close_labware_latch()
# Open labware latch
hs_module.open_labware_latch()
# Deactivate heater
hs_module.deactivate_heater()
# Deactivate shaker
hs_module.deactivate_shaker()
Thermocycler Module:
# Open lid
tc_module.open_lid()
# Close lid
tc_module.close_lid()
# Set lid temperature
tc_module.set_lid_temperature(celsius=105)
# Set block temperature
tc_module.set_block_temperature(
temperature=95,
hold_time_seconds=30,
hold_time_minutes=0.5,
block_max_volume=50 # µL per well
)
# Execute profile (PCR cycling)
profile = [
{'temperature': 95, 'hold_time_seconds': 30},
{'temperature': 57, 'hold_time_seconds': 30},
{'temperature': 72, 'hold_time_seconds': 60}
]
tc_module.execute_profile(
steps=profile,
repetitions=30,
block_max_volume=50
)
# Deactivate
tc_module.deactivate_lid()
tc_module.deactivate_block()
Absorbance Plate Reader:
# Initialize and read
result = plate_reader.read(wavelengths=[450, 650])
# Access readings
absorbance_data = result # Dict with wavelength keys
Define Liquids:
# Define liquid types
water = protocol.define_liquid(
name='Water',
description='Ultrapure water',
display_color='#0000FF' # Hex color code
)
sample = protocol.define_liquid(
name='Sample',
description='Cell lysate sample',
display_color='#FF0000'
)
Load Liquids into Wells:
# Load liquid into specific wells
reservoir['A1'].load_liquid(liquid=water, volume=50000) # µL
plate['A1'].load_liquid(liquid=sample, volume=100)
# Mark wells as empty
plate['B1'].load_empty()
Execution Control:
# Pause protocol
protocol.pause(msg='Replace tip box and resume')
# Delay
protocol.delay(seconds=60)
protocol.delay(minutes=5)
# Comment (appears in logs)
protocol.comment('Starting serial dilution')
# Home robot
protocol.home()
Conditional Logic:
# Check if simulating
if protocol.is_simulating():
protocol.comment('Running in simulation mode')
else:
protocol.comment('Running on actual robot')
Rail Lights (Flex only):
# Turn lights on
protocol.set_rail_lights(on=True)
# Turn lights off
protocol.set_rail_lights(on=False)
When using multi-channel pipettes:
# Load 8-channel pipette
multi_pipette = protocol.load_instrument(
'p300_multi_gen2',
'left',
tip_racks=[tips]
)
# Access entire column with single well reference
multi_pipette.transfer(
volume=100,
source=source_plate['A1'], # Accesses entire column 1
dest=dest_plate['A1'] # Dispenses to entire column 1
)
# Use rows() for row-wise operations
for row in plate.rows():
multi_pipette.transfer(100, reservoir['A1'], row[0])
Serial Dilution:
def run(protocol: protocol_api.ProtocolContext):
# Load labware
tips = protocol.load_labware('opentrons_flex_96_tiprack_200ul', 'D1')
reservoir = protocol.load_labware('nest_12_reservoir_15ml', 'D2')
plate = protocol.load_labware('corning_96_wellplate_360ul_flat', 'D3')
# Load pipette
p300 = protocol.load_instrument('p300_single_flex', 'left', tip_racks=[tips])
# Add diluent to all wells except first
p300.transfer(100, reservoir['A1'], plate.rows()[0][1:])
# Serial dilution across row
p300.transfer(
100,
plate.rows()[0][:11], # Source: wells 0-10
plate.rows()[0][1:], # Dest: wells 1-11
mix_after=(3, 50), # Mix 3x with 50µL after dispense
new_tip='always'
)
Plate Replication:
def run(protocol: protocol_api.ProtocolContext):
# Load labware
tips = protocol.load_labware('opentrons_flex_96_tiprack_1000ul', 'C1')
source = protocol.load_labware('corning_96_wellplate_360ul_flat', 'D1')
dest = protocol.load_labware('corning_96_wellplate_360ul_flat', 'D2')
# Load pipette
p1000 = protocol.load_instrument('p1000_single_flex', 'left', tip_racks=[tips])
# Transfer from all wells in source to dest
p1000.transfer(
100,
source.wells(),
dest.wells(),
new_tip='always'
)
PCR Setup:
def run(protocol: protocol_api.ProtocolContext):
# Load thermocycler
tc_mod = protocol.load_module('thermocyclerModuleV2')
tc_plate = tc_mod.load_labware('nest_96_wellplate_100ul_pcr_full_skirt')
# Load tips and reagents
tips = protocol.load_labware('opentrons_flex_96_tiprack_200ul', 'C1')
reagents = protocol.load_labware('opentrons_24_tuberack_nest_1.5ml_snapcap', 'D1')
# Load pipette
p300 = protocol.load_instrument('p300_single_flex', 'left', tip_racks=[tips])
# Open thermocycler lid
tc_mod.open_lid()
# Distribute master mix
p300.distribute(
20,
reagents['A1'],
tc_plate.wells(),
new_tip='once'
)
# Add samples (example for first 8 wells)
for i, well in enumerate(tc_plate.wells()[:8]):
p300.transfer(5, reagents.wells()[i+1], well, new_tip='always')
# Run PCR
tc_mod.close_lid()
tc_mod.set_lid_temperature(105)
# PCR profile
tc_mod.set_block_temperature(95, hold_time_seconds=180)
profile = [
{'temperature': 95, 'hold_time_seconds': 15},
{'temperature': 60, 'hold_time_seconds': 30},
{'temperature': 72, 'hold_time_seconds': 30}
]
tc_mod.execute_profile(steps=profile, repetitions=35, block_max_volume=25)
tc_mod.set_block_temperature(72, hold_time_minutes=5)
tc_mod.set_block_temperature(4)
tc_mod.deactivate_lid()
tc_mod.open_lid()
protocol.comment() for debugging and loggingnew_tip='once' when appropriate to save tipsCommon Issues:
For detailed API documentation, see references/api_reference.md in this skill directory.
For example protocol templates, see scripts/ directory.
まだレビューはありません。使ってみた感想をお寄せください。
概要と使いどころ
Testing patterns for PHPUnit and Playwright E2E tests. Use when writing tests, debugging test failures, setting up test coverage, or implementing test patterns for ActivityPub features.
日本語の概要は準備中です。原文の説明を表示しています。
Cloud laboratory platform for automated protein testing and validation. Use when designing proteins and needing experimental validation including binding assays, expression testing, thermostability measurements, enzyme activity assays, or protein sequence optimization. Also use for submitting experiments via API, tracking experiment status, downloading results, optimizing protein sequences for better expression using computational tools (NetSolP, SoluProt, SolubleMPNN, ESM), or managing protein design workflows with wet-lab validation.
日本語の概要は準備中です。原文の説明を表示しています。
Add unsigned integer (uint) type support to PyTorch operators by updating AT_DISPATCH macros. Use when adding support for uint16, uint32, uint64 types to operators, kernels, or when user mentions enabling unsigned types, barebones unsigned types, or uint support.
日本語の概要は準備中です。原文の説明を表示しています。
This skill should be used when the user asks to "create an agent", "add an agent", "write a subagent", "agent frontmatter", "when to use description", "agent examples", "agent tools", "agent colors", "autonomous agent", or needs guidance on agent structure, system prompts, triggering conditions, or agent development best practices for Claude Code plugins.
日本語の概要は準備中です。原文の説明を表示しています。
Master advanced AgentDB features including QUIC synchronization, multi-database management, custom distance metrics, hybrid search, and distributed systems integration. Use when building distributed AI systems, multi-agent coordination, or advanced vector search applications.
日本語の概要は準備中です。原文の説明を表示しています。
Create and train AI learning plugins with AgentDB's 9 reinforcement learning algorithms. Includes Decision Transformer, Q-Learning, SARSA, Actor-Critic, and more. Use when building self-learning agents, implementing RL, or optimizing agent behavior through experience.
日本語の概要は準備中です。原文の説明を表示しています。