本文へ移動
cccskills
無料GitHub で公開

endo-assess-bolus-calculator-settings

This skill guides clinicians to assess bolus calculator settings when reviewing pump settings or verifying carb ratio and sensitivity factor during clinic visits. It evaluates insulin-to-carbohydrate ratio, insulin sensitivity factor, glucose targets, and active insulin time for embedded bolus calculators in CSII.

インストール方法を見る

含まれるファイル(1)

  • SKILL.md3.7 KB

SKILL.md(原文)

インストールする前に、エージェントに与えられる指示の中身を確認できます。

Assess bolus calculator settings

STEP 1 — Gather Information

Collect the current insulin-to-carbohydrate ratio (ICR), insulin sensitivity factor (ISF), glucose target, and active insulin time (AIT) from the pump settings, patient logbook, or downloaded pump data. (Action: obtain these four parameters.)

STEP 2 — Rule In / Rule Out

Determine whether the patient is using an embedded bolus calculator in their CSII system. If yes, proceed to evaluate the four settings; if no, recommend education on bolus calculator use and consider enabling the feature per guideline suggestion. (Action: either assess settings or advise education/enablement.)

STEP 3 — Classify or Stratify

For each setting, classify as: Appropriate (matches individualized target based on weight, total daily dose, or recent glucose patterns), Needs Adjustment (outside expected range or inconsistent with recent hypoglycemia/hyperglycemia), or Missing/Unknown. Use a quick reference table (see below) for typical starting points. (Action: label each ICR, ISF, target, AIT.)

ParameterTypical Starting PointConsider Adjustment If
ICR (g/U)500 ÷ TDD (U/day) or weight‑basedFrequent post‑meal hyperglycemia or hypoglycemia
ISF (mg/dL per U)1800 ÷ TDD (U/day) or 100 ÷ TDDPersistent pre‑meal hyperglycemia or hypoglycemia
Glucose target (mg/dL)Individualized (often 100‑130)Mismatch with patient’s A1C goals or hypoglycemia unawareness
AIT (hours)3‑4.5 for rapid‑acting analogsShorter than insulin’s action (risk stacking) or longer (over‑correction)

STEP 4 — Decide

If any setting is classified as Needs Adjustment or Missing/Unknown, calculate a revised value using the patient’s current TDD or weight and update the pump; document the change and schedule follow‑up review in 1‑2 weeks. If all settings are Appropriate, reinforce current regimen and remind patient to report any pattern of hypoglycemia/hyperglycemia. (Action: adjust settings or maintain with education.)

Clinical Guardrails / Mimics / Pitfalls

Do not rely on universal ratios; always individualize based on TDD, weight, and recent glucose trends. Avoid making large (>20%) changes to ICR or ISF at once to prevent hypoglycemia. Remember that AIT must match the insulin’s duration of action; incorrect AIT leads to insulin stacking or inadequate correction. Do not ignore the impact of fat/protein on post‑prandial glucose when using standard bolus calculators. Never adjust settings without reviewing recent glucose data or hypoglycemia events.

Concrete Clinical Example

A 28‑year‑old with T1DM using a Medtronic 670G pump reports frequent morning hypoglycemia. Review shows ICR 1:8, ISF 1:30, target 100 mg/dL, AIT 4 hours. TDD is 32 U. Expected ICR ≈ 500/32 ≈ 15.6 g/U (1:16) and ISF ≈ 1800/32 ≈ 56 mg/dL/U. Current ICR is too aggressive (1:8) and ISF too high (1:30). After reducing basal and adjusting ICR to 1:15 and ISF to 1:45, hypoglycemia resolves without worsening hyperglycemia.

Source: Diabetes Technology—Continuous Subcutaneous Insulin Infusion Therapy and Continuous Glucose Monitoring in Adults, Endocrine Society, 2016, DOI: 10.1210/jc.2016-2534

TODO: consider adding scripts/calc.py for the endo-assess-bolus-calculator-settings calculator

レビュー

まだレビューはありません。使ってみた感想をお寄せください。

同じリポジトリのスキル

概要と使いどころ

Guide pump setting adjustments for the MiniMed 780G system based on CareLink data, using Medtronic's 3-step follow-up workflow. Use when a clinician has CareLink data for a 780G patient and wants to know what to change — which setting, by how much, and how to program it. Triggers include: "what do I adjust", "how to fix high TIR", "how to reduce hypos", "adjust ICR/ISF/basal", "SmartGuard settings", "780G pump settings review", or any question about optimising 780G therapy after reviewing a download.

日本語の概要は準備中です。原文の説明を表示しています。

dromlakhani/MD2SKILL132026年10月5日 更新

Performs corticotropin stimulation test to diagnose adrenal insufficiency when morning cortisol is indeterminate (3-15 µg/dL). Triggers include morning cortisol 3-15 µg/dL requiring further AI testing.

日本語の概要は準備中です。原文の説明を表示しています。

dromlakhani/MD2SKILL132026年10月5日 更新

Administers immediate parenteral injection of 50–100 mg hydrocortisone for suspected adrenal crisis secondary to adrenal insufficiency. Triggers include hypotension, hypoglycemia, or acute illness in a patient with known adrenal insufficiency.

日本語の概要は準備中です。原文の説明を表示しています。

dromlakhani/MD2SKILL132026年10月5日 更新

Clinicians educate adrenal insufficiency patients taking nondexamethasone glucocorticoids who initiate enzyme-inducing antiepileptic drugs about early signs of adrenal insufficiency. Trigger when an AI patient on nondexamethasone GC starts an enzyme-inducing AED such as phenytoin, carbamazepine, or oxcarbazepine.

日本語の概要は準備中です。原文の説明を表示しています。

dromlakhani/MD2SKILL132026年10月5日 更新

In central hypothyroidism patients receiving levothyroxine who initiate enzyme‑inducing antiepileptic drugs, the guideline recommends checking free T4 at least 6 weeks after AED start and increasing the levothyroxine dose if free T4 falls below the target range. Triggers include: central hypothyroidism patient on levothyroxine starting antiepileptic drug such as phenytoin, carbamazepine, or oxcarbazepine.

日本語の概要は準備中です。原文の説明を表示しています。

dromlakhani/MD2SKILL132026年10月5日 更新

Applies serum cortisol cutoffs (<3 μg/dL indicates central adrenal insufficiency; >15 μg/dL likely excludes it) when evaluating morning cortisol for suspected adrenal insufficiency. Triggers include morning cortisol measurement in suspected AI and use when interpreting morning cortisol levels for adrenal insufficiency workup.

日本語の概要は準備中です。原文の説明を表示しています。

dromlakhani/MD2SKILL132026年10月5日 更新

dromlakhani のスキルをすべて見る

このスキルの問題を報告する