endo-assess-csii-operation-ability

Assesses a patient’s ability to operate an insulin pump and make setting changes, evaluating dexterity, vision, mental health, and cognition for independent or assisted use. Triggered by phrases such as 'Check patient can manipulate pump controls' and 'Evaluate dexterity and vision for pump use'.

インストール方法を見る

含まれるファイル(1)

  • SKILL.md2.7 KB

SKILL.md(原文)

インストールする前に、エージェントに与えられる指示の中身を確認できます。

Assess ability to operate CSII and make setting changes

STEP 1 — Gather Information

Collect data on manual dexterity (button pressing, dial turning), visual acuity (reading display, distinguishing colors), mental health status (depression, anxiety), cognitive function (memory, executive function), and whether the patient operates the pump independently or with assistance. Document findings and note any specific deficits.

STEP 2 — Rule In / Rule Out

Determine if the patient can independently operate the pump and make all necessary setting changes without assistance. If yes, rule in independent capability; if no, rule out independent capability and proceed to assess needed assistance level.

STEP 3 — Classify or Stratify

For patients lacking independent capability, stratify the level of assistance required: (1) occasional assistance for complex tasks, (2) regular assistance for daily operations, (3) full dependence on caregiver for all pump functions. Assign an assistance level based on observed deficits.

STEP 4 — Decide

If independent capability is confirmed, proceed with standard CSII education and training. If assistance is needed, tailor training to patient and caregiver, consider a pump with simplified interface or larger controls, and evaluate alternative insulin delivery methods if safety is a concern.

Clinical Guardrails / Mimics / Pitfalls

Do not assume competence based on age, education, or prior pump experience alone; do not overlook subtle visual impairments such as reduced contrast sensitivity; avoid delegating pump programming to untrained family members without verification of their ability; do not ignore fluctuating mental health or cognitive status that may affect ability intermittently.

Concrete Clinical Example

A 58‑year‑old with type 1 diabetes, mild diabetic retinopathy, and osteoarthritis attempts to adjust bolus ratios; assessment shows difficulty seeing small icons and painful finger movements when pressing buttons. Decision: involve spouse for weekly pump programming, provide a pump with backlit screen and larger tactile buttons, and schedule reassessment in 3 months.

Source: Diabetes Technology—Continuous Subcutaneous Insulin Infusion Therapy and Continuous Glucose Monitoring in Adults: An Endocrine Society Clinical Practice Guideline, Endocrine Society, 2016, DOI:10.1210/jc.2016-2534

レビュー

まだレビューはありません。使ってみた感想をお寄せください。

同じリポジトリのスキル

概要と使いどころ

Guide pump setting adjustments for the MiniMed 780G system based on CareLink data, using Medtronic's 3-step follow-up workflow. Use when a clinician has CareLink data for a 780G patient and wants to know what to change — which setting, by how much, and how to program it. Triggers include: "what do I adjust", "how to fix high TIR", "how to reduce hypos", "adjust ICR/ISF/basal", "SmartGuard settings", "780G pump settings review", or any question about optimising 780G therapy after reviewing a download.

日本語の概要は準備中です。原文の説明を表示しています。

dromlakhani/MD2SKILL132026年10月5日 更新

Performs corticotropin stimulation test to diagnose adrenal insufficiency when morning cortisol is indeterminate (3-15 µg/dL). Triggers include morning cortisol 3-15 µg/dL requiring further AI testing.

日本語の概要は準備中です。原文の説明を表示しています。

dromlakhani/MD2SKILL132026年10月5日 更新

Administers immediate parenteral injection of 50–100 mg hydrocortisone for suspected adrenal crisis secondary to adrenal insufficiency. Triggers include hypotension, hypoglycemia, or acute illness in a patient with known adrenal insufficiency.

日本語の概要は準備中です。原文の説明を表示しています。

dromlakhani/MD2SKILL132026年10月5日 更新

Clinicians educate adrenal insufficiency patients taking nondexamethasone glucocorticoids who initiate enzyme-inducing antiepileptic drugs about early signs of adrenal insufficiency. Trigger when an AI patient on nondexamethasone GC starts an enzyme-inducing AED such as phenytoin, carbamazepine, or oxcarbazepine.

日本語の概要は準備中です。原文の説明を表示しています。

dromlakhani/MD2SKILL132026年10月5日 更新

In central hypothyroidism patients receiving levothyroxine who initiate enzyme‑inducing antiepileptic drugs, the guideline recommends checking free T4 at least 6 weeks after AED start and increasing the levothyroxine dose if free T4 falls below the target range. Triggers include: central hypothyroidism patient on levothyroxine starting antiepileptic drug such as phenytoin, carbamazepine, or oxcarbazepine.

日本語の概要は準備中です。原文の説明を表示しています。

dromlakhani/MD2SKILL132026年10月5日 更新

Applies serum cortisol cutoffs (<3 μg/dL indicates central adrenal insufficiency; >15 μg/dL likely excludes it) when evaluating morning cortisol for suspected adrenal insufficiency. Triggers include morning cortisol measurement in suspected AI and use when interpreting morning cortisol levels for adrenal insufficiency workup.

日本語の概要は準備中です。原文の説明を表示しています。

dromlakhani/MD2SKILL132026年10月5日 更新

dromlakhani のスキルをすべて見る

このスキルの問題を報告する